TECHNICAL BULLETIN
Intrusion GV2 Series, D8125INV Wireless Module
False Alarms on 24-Hour Points January 7, 2009
Issue Severity: Products Affected:
High: Act immediately
Medium: Bosch Security Systems, Inc.
strongly recommends you take the action(s)
described below.
Low: Advisory
• GV2 Series Control Panels
• D8125INV Wireless Interface Module
1.0 Issue
GV2 Series control panels using the D8125INV Wireless Interface Module might indicate false alarms for
24-hour wireless points.
2.0 Resolution
This problem occurs if the Debounce setting for 24-hour wireless points is set to 1.
To correct the problem, use RPS or the D5200 Programmer and navigate to POINTS (RADXPNTS) → Point
Assignments → Debounce, then make sure that all 24-hour wireless points have Debounce set to 2 or greater.
Bosch Security Systems, Inc. recommends leaving the Debounce parameter at the default value of 2.