3. Controller Functions
Para-Drehz-Glätt
Parameter protocol!
Parameter
P01
P02
P03
P04
P05
A06
Designation
RAMP 1
RPM 1
RAMP 2
RPM 2
RAMP 3
FUNCT 2
Function
Value for smoothing time constant
no function, but defined value 0 is needed!
" " " " " "
" " " " " "
" " " " " "
the smoothing set is also active with:
control input EXT POS = 1
Value range or value
0 to 11
0
0
0
0
< 32 >
S R Q
S R Q
S R Q
S R Q
S R Q
Note: Smoothing is achieved via a digital filter. The smoothing time
constant is calculated as follows:
Tg = 0.5 x 2
RAMP1
ms
In the same parameter record the speed command value smoothing
excludes the speed ramp function.
Speed command value smoothing is possible for both analogue and
digital command values.
Smoothing time constant
Figure 31: Parameters for smoothing speed command value