Bosch CC880/LP880, SC8016 Specifications Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
CC880/LP880, SC8016 | Quick Reference Guide | 5. Programming Parameters EN | 20
Bosch Security Systems | 6/04 | 4998152461B
5.17 Siren Programming
5.17.1 Siren Run Time (V1.10 to V2.03, V2.04+)
Location
660 (V1.10 to V2.03)
Default
10
0 No siren time
1 to 15 Siren time in minutes
Location
660 (V2.04+)
Default
5
0 No siren time
1 to 15 Siren time in minutes
5.17.2 Siren Sound Rate
Location
661
Default
7
0 Slowest frequency
15 Fastest frequency
5.17.3 Swinger Shutdown Count for Siren and
Dialler (V1.10 to V1.37, V1.40)
Location
662 (V1.10 to V1.37)
Default
0
0 No lockout
1 to 15 Number of times siren/dialler operate until
lockout
Location
662 (V1.40)
Default
0
0 No lockout
1 to 15 Number of times siren operate until lockout
5.18 Dialler Options Programming
5.18.1 Dialler Options 1
Location
663
1 Dialler reporting functions allowed (disabled in
V2.00, also disable Safecom)
2 Remote arming via telephone allowed
4 Upload/download via alarm link allowed
8 Terminate alarm link session on alarm
5.18.2 Dialler Options 2
Location
664
Default
0
1 Open/close reports only after alarm
2 First to open/last to close reporting (partitioned
systems only)
4 Open/Close Reports in STAY Mode allowed
8 Answering machine bypass only when armed
(V1.31+)
5.19 System Options Programming
5.19.1 System Options 1
Location
665
1 Forced arming allowed
2 Smart lockout allowed
4 Horn speaker monitor
8 Horn speaker beeps allowed
5.19.2 System Options 2
Location
666
1 Keyswitch interface, night arm station, or RE005
installed
2 Handover delay to be sequential
4 Codepad panic to be silent
8 Access denied (code retries/codepad tamper) to be
silent
5.19.3 System Options 3
Location
667
Default
0
1 Area 1 codepad connected to main data terminal
2 Modem module required for alarm link operation
4 AC fail after 1 hour (Disabled = after 2 minutes)
8 Pulse count handover allowed
5.19.4 System Options 4 (V1.10 only)
Location
668
Default
0
1 Delay audible alarm until communication complete
2 Reset alarm outputs from any area (partitioned
systems only)
4 Auto arm in AWAY mode
8 Auto arm in STAY mode 1
5.19.5 System Options 4 (V1.20+)
Location
668
Default
0
1 Delay audible alarm until communication complete
2 Reset alarm outputs from any area (partitioned
systems only)
4 Ignore AC mains fail (V1.30+)
8 Auto arm in STAY Mode 1
5.19.6 System Options 5 (V1.37+)
Location
897
Default
0
1 Send Test Report at end of siren time
2 Power up in disarmed state (re-boot)
4 Internal crystal to keep time (V1.40+)
8 Reserved
5.19.7 System Options 6 (V1.33+)
Location
898
1 Busy tone detection for domestic dialling allowed
2 Kiss-off detection for domestic dialling allowed
4 Extend acknowledge time from 30 seconds to
60 seconds
8 If battery failed, restrict battery test only on arming
(V1.35+)
Page view 19