Bosch D7212GV2 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
Mounting Skirt 1
Faceplate with D7212GV2 Label 1
Technical specifications
Communications
SDI Bus A (+): 9 VDC
4572 m (15,000 ft)
SDI Bus B (-): 9 VDC
4572 m (15,000 ft)
Telephone Connection: RJ31X or RJ38X
Environmental Considerations
Relative Humidity: 5% to 85% at +30°C (+86°F),
non-condensing
Temperature (Operating): 0°C to +50°C (+32°F to +120°F)
Number of…
Areas: 4
Custom Functions: 4
Programmable Relay Outputs: 27
Events: Store up to 1,000
Parallel Printers: 1
Passcode Users: 99, plus 1 service passcode
Points: 40 (eight on-board, up to 32
off‑board)
RF Points: 32
SKEDs: 40
Power Requirements
Current Draw (Minimum): 200 mA
Current Draw (Maximum): 500 mA
Output (Alarm): 2 A at 12 VDC
Output (Auxiliary, Continuous
Power, and Switched Auxiliary
combined):
1.4 A at 10.2 VDC to 13.9 VDC
Voltage (Operating): 12 VDC
Voltage (AC): 16.5 VAC 40 VA plug-in
transformer (D1640)
Voltage (DC): Up to 2 12 VDC, 7 Ah
sealed lead acid
rechargeable batteries
Up to 2 12 VDC, 18 Ah
sealed lead acid
rechargeable batteries
The D7212GV2 Control Panel is available exclusively to
Bosch Certified Security Dealers (BCSD).
5
| D7212GV2 Control Panel
Page view 4
1 2 3 4 5 6 7 8

Comments to this Manuals

No comments