Bosch SC8016 Installation Guide

Browse online or download Installation Guide for Security access control systems Bosch SC8016. Bosch SC8016 Installation guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - ST150 SAFECOM Central Station

ST150 SAFECOM Central StationOperation and Installation Guide

Page 2

ST150System OperationST150 SAFECOM Central Station Operation Manual4998122249B Page 10 © 2002 RadionicsThe operator login is complete. You are now rea

Page 3 - Table of Contents

ST150System OperationST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 11 4998122249BERROR - Blinking white on red or blinking blac

Page 4 - Contents

ST150System OperationST150 SAFECOM Central Station Operation Manual4998122249B Page 12 © 2002 RadionicsNOTE: See SAFECOM Record of Events Messages on

Page 5 - 1. System Overview

ST150System OperationST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 13 4998122249B• ESC - Allows the operator to Exit a currentl

Page 6 - System Overview

ST150System OperationST150 SAFECOM Central Station Operation Manual4998122249B Page 14 © 2002 RadionicsF1 Select F5 Logoff F6 History F7 AccountF1 Upd

Page 7

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 15 4998122249B3. Installing and Communicating with RadioCommunicators3.1.

Page 8

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 16 © 2002 Radionics• The SC9000 transmits a message to the Radio Communicator th

Page 9 - 2. System Operation

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 17 4998122249B3.4. Temporarily Stop Communications with a Radio Communicat

Page 10 - System Operation

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 18 © 2002 Radionics(378). There are now two identical Radio Communicator accounts

Page 11

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 19 4998122249B4. Radio Communicator Procedures4.1. SC21044.1.1. SC2104 Al

Page 12

ST150ST150 SAFECOM Central Station Operation Manual4998122249B Page 2 © 2002 Radionics

Page 13

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 20 © 2002 Radionics The parameters required to be program

Page 14

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 21 4998122249B• VAccount - 0001 to FFFF: The Virtual Account Number is use

Page 15 - Communicators

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 22 © 2002 Radionics• Delay Short - Y or N: This parameter will program in a dela

Page 16

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 23 4998122249B• Power Trouble - Yes or No: “ Y “ indicates that the SC2104

Page 17

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 24 © 2002 RadionicsBypassing SC2104 Inputs from the SC9000The SC9000 provides the

Page 18 - 214 DEACTIVATED

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 25 4998122249B4.2.2 Programming an SC8016 Account into the SC9000There ar

Page 19 - 4.1. SC2104

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 26 © 2002 Radionicsis HOURS : MINUTES : SECONDS. A Poll Interval of 00:00:00 (all

Page 20

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 27 4998122249B• Panel Arm XLAT assigns the Panel Arm output to one of th

Page 21

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 28 © 2002 Radionics• Power Trouble ( Yes or No ) : “ Y “ indicates that the SC8

Page 22 - Operator

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 29 4998122249BTo Send a Manual Output Disable Command to an SC8016 from the

Page 23

ST150ContentsST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 3 4998122249BTable of Contents1. System Overview ...

Page 24 - 4.2 SC8016

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 30 © 2002 RadionicsSC9000 Year 2000 ComplianceThe Compaq 386 PC that ships as pa

Page 25

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 31 4998122249BNOTE: Press the ESC=Abort Backup option from the command wind

Page 26

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 32 © 2002 Radionics• Enter new and edit old alarm panel signal definitions in th

Page 27

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 33 4998122249B5.2.1. Using F3=System Functions Menu Page #1The following i

Page 28

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 34 © 2002 Radionics• Remote reports on VLine? - Y or N: Allows the operator to s

Page 29 - 5. System Commands

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 35 4998122249B5.3. The F4=Channel Functions OverviewThe F4=Channel Functio

Page 30 - To Make a Backup Copy

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 36 © 2002 RadionicsThere are 8 Digital Translation Tables (XLATs) (1 through 8).

Page 31 - 5.1.3. ID Startups

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 37 4998122249B5.7. Entering SAFECOM Output Control Definitions (Output Tra

Page 32

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 38 © 2002 Radionics5.11. SAFECOM Record of Events MessagesA Record of Events Mes

Page 33

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 39 4998122249B• NNN CONFLICT XXXXXXXXX - Priority #1 - Not Sent to Automat

Page 34

ST150ContentsST150 SAFECOM Central Station Operation Manual4998122249B Page 4 © 2002 Radionics

Page 35 - To Enter the User Codes

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 40 © 2002 Radionics• NNN priority granted - Priority #3 - Not Sent to Automatio

Page 36

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 41 4998122249B• NNN tamper restore - Priority #2 - Cancels a previously re

Page 37

SC9000ST150 SAFECOM Central Station Operation Manual4998122249B Page 42 © 2002 Radionics5.13. Automation : Alarm Event WindowsThe ST150 incorporates

Page 38

SC9000ST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 43 4998122249B

Page 39

© 2002 Radionics, a division of Detection Systems, Inc.PO Box 80012, Salinas, CA 93912-0012, USACustomer Service: (800) 538-5807 Technical Support: (8

Page 40

ST150System OverviewST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 5 4998122249B1. System Overview1.1. SAFECOM System OverviewSA

Page 41

ST150System OverviewST150 SAFECOM Central Station Operation Manual4998122249B Page 6 © 2002 RadionicsBuilt-in system checks allow the ST150 to deliver

Page 42 -

ST150System OverviewST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 7 4998122249B1.5. SAFECOM SC9000 Receiver Software Requireme

Page 43

ST150System OverviewST150 SAFECOM Central Station Operation Manual4998122249B Page 8 © 2002 Radionics

Page 44

ST150System OperationST150 SAFECOM Central Station Operations Manual© 2002 Radionics Page 9 4998122249B2. System Operation2.1. SAFECOM System Start-U

Comments to this Manuals

No comments