16 en | Installation IP Camera 200 Series
AM18-Q0616 | v1 | 2012.02 Installation Manual Bosch Security Systems
3.5 I/O connector
Figure 3.3 I/O connector pins
Cut back 5 mm (0.2 in) of insulation.
Relay switching capability: Max. voltage 24 VAC or 24 VDC.
Max. 1 A continuous, 12 VA.
Alarm in: Short or +5 VDC activation.
Alarm input configurable as active low or active high.
Function Wire Color
Relay out AWG20 Grey
AWG20 Red
Alarm input AWG30 Orange
AWG30 Brown
5 mm
(0.2 in)
In: AWG30
Out: AWG20