Bosch series VG4-300 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
Environmental
Model In-Ceiling Indoor
Pendant
EnviroDome®
Design
Rating
Plenum Rated IP66 IP66
Operatin
g Temp.
–10°C to 50°C
(14°F to
122°F)
–10°C to 50°C
(14°F to
122°F)
–40°C to 50°C
(–40°F to 122°F)
Storage
Temp.
–40°C to 60°C
(–40°F to
140°F)
–40°C to 60°C
(–40°F to
140°F)
–40°C to 60°C
(–40°F to 140°F)
Humidity 0% to 90%
relative, non-
condensing
0% to 90%
relative, non-
condensing
0% to 100%
relative,
condensing
Protectio
n
IP 66, IK 8 (IEC 62262)
Miscellaneous
Sectors/Titling 16 independent sectors with 20-character titles/
sector
Camera Setup/
Control
Biphase, RS-232, RS-485, Bilinx
10
(coax)
Communication
s Protocols
Biphase, Bilinx
10
, Pelco P, and Pelco D
Pre-positions 99, each with 20-character titles
Guard Tours Two (2) types of tours:
Recorded tours - two (2), total duration
15 minutes
Preset tour - one (1), consisting of up to 99
scenes, consecutively and (1) customized
up to 99 scenes
Supported
Languages
Czech, Dutch, English, French, German, Italian,
Polish, Portuguese, Russian and Spanish
10 Bilinx not available on Ethernet models.
Cable Compensation
Max Distance With Pre-comp OFF With Pre-comp ON
RG-59/U 1000 ft (300 m) 2000 ft (600 m)
RG-6/U 1500 ft (450 m) 3000 ft (900 m)
RG-11/U 2000 ft (600 m) 4000 ft (1200 m)
Cat5/UTP
(Passive receiver)
750 ft (225 m) 1500 ft (450 m)
User Connections
Power (Camera) 21-30 VAC, 50/60 Hz
Power (Heater) 21-30 VAC, 50/60 Hz
Biphase ± Control Data
Audio Line In
11
9 K Ohm typ, 5.5 Vp-p max
RS-232 RX/TX or RS-485 ± - optional control data
(dip switch selectable)
Video BNC/UTP
12
EOLR Alarm Inputs (2) Programmable for
“normally open”, "normally closed",
“normally open-supervised”, “normally
closed-supervised”
Alarm Inputs (5) Programmable for
“normally open” or "normally closed"
Relay Out (1) Dry contact output rating:
2 A @ 30 VAC
Open Collector Outputs
(3)
32VDC@150 ma max
11 With Ethernet models, the biphase ± can optionally be used as the audio line in
connector.
12 Ethernet models have no UTP analog output only BNC (coax).
Mounts/Accessories
Pendant Mounts
Arm Mounts
Wall Arm (No Transformer) VG4-A-PA0
Wall Arm (120/230 VAC Transformer) VG4-A-PA1 /
VG4-A-PA2
Wall Arm (120/230 VAC Transformer
and Fiber Optics)
VG4-A-PA1F /
VG4-A-PA2F
Optional Mounting Plates for Arm Mounts
Corner Mounting Plate VG4-A-9542
Mast (Pole) Mounting Plate VG4-A-9541
Pipe Mounts
Pipe Mount Cap VG4-A-9543
Roof Mounts
Roof (Parapet) Mount VG4-A-9230
Optional Mounting Plates for Roof Mounts
Flat Roof Adapter for Parapet Mount LTC 9230/01
Power Supplies
Outdoor Power Supply Box
(120/230 VAC Transformer)
VG4-A-PSU1 /
VG4-A-PSU2
Outdoor Power Supply Box
(120/230 VAC Transformer and Fiber
Optics)
VG4-A-PSU1F /
VG4-A-PSU2F
Extended temp heater
module extends temperature
range to –60°C (–76°F) for EnviroDome
®
only
VG4-SHTR-XT
6 | AutoDome 300 Series PTZ Camera System
Page view 5
1 2 3 4 5 6 7 ... 20

Comments to this Manuals

No comments