Page 1 - Fire Alarm Control Panel

D2071AENOperation & Installation GuideFire Alarm Control Panel

Page 2 - Contents

Bosch | 09/04 | 74-06200-000-F10D2071A | Operations & Installation Guide |2.1 Earth Ground Wiring Only use Terminal 3, not telephone or electrical

Page 3 - FCC Notice

11Bosch | 09/04 | 74-06200-000-F• If the time specified in the retard time accumulates inone or more successive alarm activations, theD2071A transmits

Page 4 - 1.0 Overview

Bosch | 09/04 | 74-06200-000-F12D2071A | Operations & Installation Guide |2.3.3 Mode 3Mode 3 (Figure 6) uses a 1.8 kΩ EOL resistor at the endof th

Page 5 - 1.5.1 Mandatory Connections

13Bosch | 09/04 | 74-06200-000-F2.4.2 WiringConnect only low voltage power sources and devices toTerminals 16, 17, and 18. Do not use the D2071AStandb

Page 6 - 1.7 Receiving Equipment

Bosch | 09/04 | 74-06200-000-F14D2071A | Operations & Installation Guide |Set the 12 V Mode to YES. Refer to Section 2.7.1 Batteryfor battery inst

Page 7

15Bosch | 09/04 | 74-06200-000-FRestoral ZN 9 Exceptions: If a battery is not connectedto the D2071A when AC power is connected, the controlpanel send

Page 8

Bosch | 09/04 | 74-06200-000-F16D2071A | Operations & Installation Guide |Refer to Section 6.0 Troubleshooting on page 24 for help indetermining t

Page 9 - 300 mA)

17Bosch | 09/04 | 74-06200-000-F2.9.1 Screw Mounting1. Select the mounting location in the enclosure.2. Position the D2071A in the desired location.3.

Page 10 - 2.1 Earth Ground Wiring

Bosch | 09/04 | 74-06200-000-F18D2071A | Operations & Installation Guide |3.0 Programming The information in this section is not intended to be a

Page 11

19Bosch | 09/04 | 74-06200-000-FD2071A | Operations & Installation Guide | 3.0 Programming3.2 Function KeysTable 7 identifies the six function

Page 12

Bosch | 09/04 | 74-06200-000-F2D2071A | Operations & Installation Guide |ContentsContents1.0 Overview ...

Page 13 - 2.6 Primary Power Supply

Bosch | 09/04 | 74-06200-000-F20D2071A | Operations & Installation Guide |3.8 Program ModulesUnlike larger Bosch products, the D2071 ProductHandle

Page 14

21Bosch | 09/04 | 74-06200-000-FPriPh# Default: Blank Selections: 0 to 9, B to F, or Blank Use to select the primary receiver telephone number.Yo

Page 15 - 2.8 Telephone Connections

Bosch | 09/04 | 74-06200-000-F22D2071A | Operations & Installation Guide |Reset Time Default: 0 Selections: 0 to 90 Use to program the reset

Page 16 - 2.0 Installation

23Bosch | 09/04 | 74-06200-000-F5.0 Receiver ReportsD2071A | Operations & Installation Guide | 5.0 Receiver Reports Title Description ALARM ZN

Page 17

Bosch | 09/04 | 74-06200-000-F24D2071A | Operations & Installation Guide |6.0 TroubleshootingTo help prevent problems, read the preceding sections

Page 18 - 3.0 Programming

25Bosch | 09/04 | 74-06200-000-F6.3 Trouble Zone ERefer Table 10 on page 23 for the causes of theTROUBLE ZN E Report.If TROUBLE ZN E Reports regularly

Page 19 - Table 8: Tones

Bosch | 09/04 | 74-06200-000-F26D2071A | Operations & Installation Guide |6.5 Zones Problems 6.6 Trouble Zone 9A TROUBLE ZN 9 Report tells you the

Page 20 - 4.0 Program Record

27Bosch | 09/04 | 74-06200-000-FD2071A | Operations & Installation Guide | 7.0 Specifications7.0 Specifications Power Input 12 VAC, 20 VA with

Page 21 - Retard Time

Bosch130 Perinton ParkwayFairport, NY 14450-9199 USACustomer Service: (800) 289-0096Technical Support: (888) 886-6189© 2004 Bosch74-06200-000-F

Page 22 - Reset Time

3Bosch | 09/04 | 74-06200-000-FD2071A | Operations & Installation Guide | FCC NoticeFCC NoticeThe D2071A Fire Alarm Control Panel (FACP)generates,

Page 23 - 5.0 Receiver Reports

Bosch | 09/04 | 74-06200-000-F4D2071A | Operations & Installation Guide |1.0 OverviewThe D2071A Fire Alarm Control Panel (FACP) is athree-zone dig

Page 24 - 6.0 Troubleshooting

5Bosch | 09/04 | 74-06200-000-F1.5.1 Mandatory ConnectionsTo comply with the NFPA 72 Central Station Fire or NFPA 72 Remote Station Signaling Service,

Page 25 - Programmer

Bosch | 09/04 | 74-06200-000-F6D2071A | Operations & Installation Guide |1.6 Slave Communicator ApplicationsTo use the D2071A as a slave communica

Page 26 - Table 12: Zone Problems

7Bosch | 09/04 | 74-06200-000-FD2071A | Operations & Installation Guide | 1.0 Overview1.8.5 Phone Line Trouble LEDThis yellow Phone Line Troubl

Page 27 - 7.0 Specifications

Bosch | 09/04 | 74-06200-000-F8D2071A | Operations & Installation Guide |2.0 InstallationSome terminals are wired differently for the stand-alone

Page 28 - Fairport, NY 14450-9199 USA

9Bosch | 09/04 | 74-06200-000-FD2071A | Operations & Installation Guide | 2.0 Installation 1. Do not connect earth ground when connected to a