VideoJet X10 Operation | en 107
Bosch Security Systems Installation and Operating Manual V3.0 | 2007.09
6.9.4 Connecting with a Terminal Program
Various requirements must be met in order to operate with a terminal program (see
Abschnitt 8.8 Communication with Terminal Program, Seite 118).
1. Start the terminal program and enter the command 1 in the main menu to switch to the
IP menu.
2. Enter the command 4 in the IP menu to change the remote IP address, then enter the IP
address of the unit you wish to connect to.
3. Enter the command 0 to return to the main menu and then enter the command 4 to
switch to the Rcp+ menu.
4. In the Rcp+ menu, enter the command 5 to activate the automatic connection.
6.9.5 Closing the Connection with a Terminal Program
1. Start the terminal program and enter the command 4 in the main menu to switch to the
Rcp+ menu.
2. In the Rcp+ menu, enter the command 5 to deactivate the automatic connection.