Bosch GGS 6 S PROFESSIONAL Operations Instructions Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 286
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
English | 23
Bosch Power Tools 1 609 929 S82 | (2.11.10)
Quick-clamping Nut
(GGS 6 S) (see figure C)
For convenient changing of grinding tools with-
out the use of additional tools, you can use the
quick-clamping nut 8 instead of the clamping
nut 1.
f Quick-clamping nut 8 may not be used for
brushing.
Use only a flawless, undamaged quick-clamp-
ing nut 8.
When screwing on, pay attention that the side
of the quick-clamping nut 8 with printing does
not face the grinding disc; the arrow must
point to the index mark 17.
A properly attached, undamaged quick-clamp-
ing nut can be loosened by hand when turning
the knurled ring in anticlockwise direction. Nev-
er loosen a tight quick-clamping nut with pli-
ers. Always use the two-pin spanner 16.
Dust/Chip Extraction
f Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one’s health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in
connection with wood-treatment additives
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
Provide for good ventilation of the work-
ing place.
It is recommended to wear a P2 filter-
class respirator.
Observe the relevant regulations in your
country for the materials to be worked.
f Prevent dust accumulation at the work-
place. Dusts can easily ignite.
Operation
Starting Operation
f Observe correct mains voltage! The voltage
of the power source must agree with the
voltage specified on the nameplate of the
machine. Power tools marked with 230 V
can also be operated with 220 V.
Switching On and Off
To start the power tool, firstly push the safety
switch against starting 7 toward the front and
afterwards press and hold the On/Off switch 6.
To lock the pressed On/Off switch 6, push the
lock-on button 7 further toward the front.
To switch off the power tool, release the On/Off
switch 6, or when it is locked, briefly press the
On/Off switch 6 and then release it.
f Check grinding tools before using. The
grinding tool must be mounted properly
and be able to move freely. Carry out a test
run for at least one minute with no load. Do
not use damaged, out-of-centre or vibrating
grinding tools. Damaged grinding tools can
burst and cause injuries.
Working Advice
Optimum grinding results are achieved when
the grinding tool is moved uniformly back and
forth with light pressure. Pressure that is too
strong reduces the performance capability of
the machine and causes the grinding tool to
wear more quickly.
Maintenance and Service
Maintenance and Cleaning
f Before any work on the machine itself, pull
the mains plug.
f For safe and proper working, always keep
the machine and ventilation slots clean.
OBJ_BUCH-1050-002.book Page 23 Tuesday, November 2, 2010 3:50 PM