WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance
or additional information consult a qualified installer,
service agency or the gas supplier.
Upon completion of the installation, these instructions
should be handed to the user of the appliance for future
reference.
In the Commonwealth of Massachusetts this product
must be installed by a licensed plumber or gas fitter.
INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC
INSTANTANEOUS TYPE WATER HEATERS FOR USE WITH NATURAL AND
LIQUEFIED PETROLEUM GAS
MODEL 125B LP and 125B NG (Flow Modulated)
Suitable for heating potable water only
Not approved for space heating purposes
Intended for variable flow applications with steady cold water inlet temperatures only
WARNING
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable,
combustible or corrosive vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any
phone in your building.
- Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Specifications....................................... Page 2
Rules for safe operation ..................... Page 4
Locating the Heater ............................ Page 4
Combustion Air Requirements .......... Page 5
Mounting the Heater ........................... Page 6
Venting the Heater .............................. Page 7
Gas Connections ..............................Page 10
Water Connections ...........................Page 12
Safety before lighting the pilot .......Page 12
Lighting instructions ..........................Page 13
Setting water temperature...............Page 13
Maintenance & Service....................Page 13
Trouble Shooting ................................Page 14
Diagram of AquaStar ........................Page 19
Components and Parts List ............ Page 20
TABLE OF CONTENTS
6 720 607 030 US (03.09) AL
Page view 0
1 2 ... 24

Summary of Contents

Page 1 - TABLE OF CONTENTS

WARNING: Improper installation, adjustment,alteration, service or maintenance can cause injury orproperty damage. Refer to this manual. For assistanc

Page 2 - UNPACKING THE AQUASTAR HEATER

10 6 720 607 030GAS LINE SIZING-It is strongly recommended that the Natural Gas pipebe Black Iron pipe the entire distance from the outsidemeter to th

Page 3 - AQUASTAR MODEL 125B

116 720 607 030GAS PIPING, CONNECTIONS and Gas RegulatorBefore connecting the gas supply, check the rating plate on the right side of the front cover

Page 4 - FOR SAFE OPERATION

12 6 720 607 030WATER CONNECTIONSInstall the heater centrally in the building if possible andmake hot water piping runs as short as possible When f

Page 5 - CLEARANCES

136 720 607 030LIGHTING INSTRUCTIONS (as seen on front coverof heater)1. STOP! Read the safety information above on this plate.2. The Gas valve must b

Page 6 - MOUNTING INSTALLATION

14 6 720 607 030To clean the pilot burner and/ or the pilot orifice : Turnoff the gas at the unit. Remove the cover of the heater. Todo so, pull off

Page 7 - Figure B

156 720 607 0303. Poor thermocouple connection at the electromagnetNote: Electromagnet is part #8707201012 located on theright side of the gas valve b

Page 8 - MASONRY CHIMNEYS

16 6 720 607 0305. Crossover in household plumbingThe AquaStar burner activates when there is sufficient waterpressure drop in the AquaStar water valv

Page 9 - 96 720 607 030

176 720 607 030HOT WATER TEMPERATURE FLUCTUATES / UNITDEACTIVATED1. Unbalanced pressure in waterlinesThe added restriction caused by the Aquastar

Page 11 - FOR LP GAS

196 720 607 030Fig. 12 - Diagram of AquaStar 125 B 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gaspressure test nipple 4. Main gas burn

Page 12 - THE PILOT

2 6 720 607 030This well engineered, gas water heater has all the fea-tures a water heater should have:It operates on the principle of heating water i

Page 13 - BACK OF THIS MANUAL

20 6 720 607 030Fig. 13 - INTERIOR COMPONENTS DIAGRAM AND PARTS LIST

Page 14

216 720 607 030Fig. 13INTERIOR COMPONENTS DIAGRAMAND PARTS LIST 125B1 Cover 8 705 421 0252 Temperature adjustment knob 8 702 000 1113Temperature adjus

Page 15 - 156 720 607 030

22 6 720 607 030LIMITED WARRANTYAquastar06.03GeneralAquastar water heaters are warranted by the Manufacturer(BOSCH) through Controlled Energy Corp. C

Page 16 - 16 6 720 607 030

236 720 607 030Fig. 14 - Flow chart of Aquastar 125 B

Page 17 - 176 720 607 030

Replacement Parts available from North AmericanDistributorCONTROLLED ENERGY CORP.340 Mad River ParkWaitsfield, Vermont 05673Phone 800-642-3111Fax (802

Page 18 - 18 6 720 607 030

36 720 607 030MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NONCOMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONSFRONT VIEW SIDE VIEWAQUA

Page 19 - Diagram of AquaStar 125 B

4 6 720 607 030GENERAL RULES TO FOLLOWFOR SAFE OPERATION1. You should follow these instructions when you install yourheater. In the United States: Th

Page 20 - 20 6 720 607 030

56 720 607 030Fig. 1 - Water heater drain plug WARNING: Flammable materials, gasoline,pressurized containers, or any other items or article

Page 21 - AND PARTS LIST 125B

6 6 720 607 030Expansion and contraction of piping due to changing watertemperature in the pipes imparts movement to the heaterwhich, if mounted direc

Page 22 - LIMITED WARRANTY

76 720 607 030Vent pipe connection. WARNING: Do not reduce the vent pipe size. See Fig. 4 for high altitude installationsThe heater must be vented t

Page 23 - 236 720 607 030

8 6 720 607 030MASONRY CHIMNEY: Masonry chimneys shall be built and installed in accordance with NFPS 211 or local codes. A minimum5” diameter gas ven

Page 24 - CONTROLLED ENERGY CORP

96 720 607 030To check the draft:Close all doors and windows to the outside.Turn on all appliances that force air out of the building.These inc