Maintenance and service
5.8 Program button
Fig. 63 “Program” key
5.8.1 Memorizing selected temperature
B Press buttons or to select desired
temperature.
B Hold Program” button for 3 seconds to save
temperature.
When LCD stops blinking, temperature is saved in
memory.
Using “Program” function
In order to select memorized temperature
B Press “Program” key.
LCD shows pre-memorized temperature, which is now
the hot water selected temperature.
5.9 Locked condition
This condition is only valid for appliances with one or
more remote controls installed.
Fig. 64 Locked condition
Whenever LCD shows the temperature setting
cannot be adjusted because the appliance is in use by
another user who has already selected a different
temperature. Appliance will be automatically unlock 5
minutes after closing hot water tap.
6 Maintenance and service
6.1 Annual maintenance
(To remove front cover, see page 7.)
Venting System
Venting system - inspect inside of flue pipe for any
blockage or restriction. Observe burner flames
during heater operation. (front cover must be
removed). Inspect the combustion air inlet pipe for
blockage or debris. Inspect combustion air and
exhaust terminations for blockage or debris.
Combustion Chamber
Inspect burner observation window (Fig. 77, #14) for
cracks or spillage of flue gases. Observe burner
flames during heater operation. Flames should be
steady and blue with no signs of yellowing. Yellow
burner flames are an indication of improper
combustion. Refer to Section 3.4, page 24 & & 3.3,
page 10 of this manual to verify exhaust system and
combustion air supply meets manufacturer's
specifications.
Pressure Relief
Manually open the pressure relief valve to ensure
proper operation.
Warning: Always shut off the electrical
power supply, shut off the manual gas
valve and shut off the water valves when
servicing.
Caution:
B Check and clean the complete water
heating system once a year.
B Carry out maintenance if necessary.
Immediately repair defects to avoid
damage to the system.
Annual maintenance table
1. Inspect venting system
2. Inspect heat exchanger
3. Inspect burner
4. Inspect condensate trap
5. Inspect water filter
Table 23 Annual maintenance