GWH 425 PN
INDOOR MODEL
Flow Modulated with Standing pilot
Suitable for heating potable water only - Not approved for space heating purposes
(Intended for variable flow applications with steady cold water inlet temperatures)
GWH-425-PN-N
GWH-425-PN-L
6 720 608 034 US (06.05) AL
Warning: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any other
appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult a
qualified installer, service agency or the gas
supplier.
In the Commonwealth of Massachusetts this
product must be installed by a licensed plumber or
gas fitter.
Upon completion of the installation, these
instructions should be handed to the user of the
appliance for future reference.
What to do if you smell gas
Close gas valve. Open windows.
Do not try to light any appliance
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Page view 0
1 2 ... 28

Summary of Contents

Page 1 - GWH 425 PN

GWH 425 PNINDOOR MODELFlow Modulated with Standing pilotSuitable for heating potable water only - Not approved for space heating purposes(Intended for

Page 2 - 1 Warning

6 720 608 03410Installation instructionsMasonry chimneyMasonry chimneys shall be built and installed inaccordance with NFPS 211 or local codes.

Page 3 - 2 Appliance details

6 720 608 034Installation instructions113.7 Gas piping & connectionsBefore connecting the gas supply, check the ratingplate on the right si

Page 4 - B Type of gas

6 720 608 03412Installation instructionsFOR NATURAL GASMaximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and

Page 5 - Fig. 4 Minimum clearances

6 720 608 034Installation instructions133.8 Measuring gas pressureConnecting manometerB Shut off gas.B Remove front cover and locate inlet gas

Page 6 - 3 Installation instructions

6 720 608 03414Operation instructions3.10 Recirculation applicationSince recirculation through the heater is notpermissible, the following drawi

Page 7 - 3.4 Mounting Heater

6 720 608 034Operation instructions154.2 Lighting instructionsB STOP! Read the previous safety information.B The gas valve must be turned off by slidi

Page 8

6 720 608 03416Operation instructions4.4 Setting the water temperatureThe GWH 425 PN has a gas control that modulatesburner input in respon

Page 9 - 3.6 Venting

6 720 608 034Maintenance and service175 Maintenance and service5.1 Maintenance intervalsThe GWH 425 PN requires periodic maintenance. The below time m

Page 10 - H (minimum) height

6 720 608 03418Maintenance and service5.4 Main burnersThe main burner flames should be blue, with a moreintense blue cone in the center

Page 11 - 6 720 608 034

6 720 608 034Troubleshooting196 Troubleshooting6.1 IntroductionMany of the questions customers ask regardingoperation of this unit can be answer

Page 12

6 720 608 0342IndexIndex1 Warning 22 Appliance details 32.1 GWH 425 PN specifications (Technical data) 32.2 Unpacking the GWH 425 PN heater 42.3 G

Page 13 - 3.9 Water connections

6 720 608 03420Troubleshooting6. Verify pilot flame completely engulfs thethermocouple tip. If pilot is too small, clean pilot orifice(see chap

Page 14 - 4 Operation instructions

6 720 608 034Troubleshooting216.7 Water is too hot1. Verify gas type indicated in rating sticker located onright-hand side of cover, coincides wi

Page 15 - 4.3 To turn off appliance

6 720 608 03422Troubleshootingthe way clockwise, the flow rate should be close to2gpm, filling the jug in 15 seconds. With thetempe

Page 16 - 1 Retaining clip

6 720 608 034Protecting the environment237 Protecting the environment PackingThe packing box may be fully recycled as confirmed bythe recycling symbol

Page 17 - 5 Maintenance and service

6 720 608 03424Interior components and diagram parts list8 Interior components and diagram parts list8.1 Interior componentsFig. 28 Functional scheme4

Page 18 - 5.6 Mineral scale build-up

6 720 608 034Interior components and diagram parts list258.2 Components diagramFig. 29 Components Diagram435049324846452829303125171819202123262427333

Page 19 - 6 Troubleshooting

6 720 608 03426Interior components and diagram parts list8.3 Parts listItemDescriptionReference1 Front cover 8 705 431 246 02 Shield 8 705 506 817 03

Page 20

6 720 608 034Fifteen Year Limited Warranty279 Fifteen Year Limited WarrantyGeneralBOSCH PRO water heaters are warranted by theManufacturer (BO

Page 21

Recycled paper © 2006 BBT NORTH AMERICA CORPORATION, Waitsfield, VT all rights reservedVULCANO Termodomésticos S.A.Estrada de Cacia3801 - 856 Aveiro -

Page 22

6 720 608 034Appliance details32 Appliance details2.1 GWH 425 PN specifications (Technical data)Approved in US/CanadaCapacityGWH 425 PN: 4.3 GPMMaximu

Page 23 - 7 Protecting the environment

6 720 608 0344Appliance details2.2 Unpacking the GWH 425 PN heaterThis heater is packed securely.Before installing the unit, be certain you have theco

Page 24 - 8.1 Interior components

6 720 608 034Appliance details52.4 Dimensions and installation clearancesFig. 3 Dimensions in Inches and (mm)4 Heat exchanger5 Burner10 Temperature co

Page 25 - 8.2 Components diagram

6 720 608 0346Installation instructions3 Installation instructions3.1 IntroductionPlease follow these instructions. Failure to followinstruction

Page 26 - 8.3 Parts list

6 720 608 034Installation instructions73.4 Mounting HeaterRemove cover and inspect.B Remove the temperature control.B Unscrew the cover fixing screws,

Page 27

6 720 608 0348Installation instructions3.5 Combustion air requirementsThe BOSCH PRO water heater holds cold water in itscopper heat exchanger and wate

Page 28

6 720 608 034Installation instructions93.6 Venting B Minimum vent pipe diameter: 5 inchesB Minimum vertical vent height: 6 feet, with no elbowsB Estab