Bosch EX14N User Manual Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
ISC-BPR2-
W12
ISC-BPR2-
WP12
ISC-BPQ2-
W12
ISC-BDL2-
WP6
ISC-BDL2-
W12
ISC-BDL2-
WP12
ISC-PPR1-
W16
ISC-PDL1-
W18
ISC-PPR1-
WA16
ISC-PDL1-
WA18
ISC-PDL1-
WC30
Type
PIR PIR Quad PIR
TriTech
(PIR+MW)
TriTech
(PIR+MW)
TriTech
(PIR+MW)
PIR
TriTech
(PIR+MW)
PIR
TriTech +
(PIR+MW)
TriTech Curtain
(PIR+MW)
Anti-Mask
No No No No No No No No Yes Yes No
Certification
UL UL UL UL UL UL UL UL UL UL UL
Pet / Small Animal
Immunity
No
On / Off
Selectable
45 lb
(20 k
g
)
No
On / Off
Selectable
100 lb
(45 k
g
)
No
On / Off
Selectable
100 lb
(45 k
g
)
Yes
10 lb
(4.5 kg)
Yes
10 lb
(4.5 kg)
Yes
10 lb
(4.5 kg)
Yes
10 lb
(4.5 kg)
No
Coverage / Range
40 x 40 ft
(12 x 12 m)
40 x 40 ft
(12 x 12 m)
40 x 40 ft
(12 x 12 m)
20 x 20 ft
6 x 6 m
40 x 40 ft
(12 x 12 m)
40 x 40 ft
(12 x 12 m)
50 x 70 ft
(16 x 21 m)
60 x 80 ft
(18 x 25 m)
50 x 70 ft
(16 x 21 m)
60 x 80 ft
(18 x 25 m)
100 x 10 ft
(30 x 3 m)
False Alarm Immunity
●●○○ ●●●○ ●●○○ ●●●● ●●○○ ●●●● ●●○○ ●●●○ ●○○○ ●●○○ ●●●○
Catch Performance
●●○○ ●●○○ ●●●○ ●●○○ ●●○○ ●●○○ ●●●○ ●●●○ ●●●● ●●●● ●●●○
Mounting Height
7 – 9 ft
(2.2 – 2.75 m)
7 – 9 ft
(2.2 – 2.75 m)
7 – 9 ft
(2.2 – 2.75 m)
7 – 9 ft
(2.2 – 2.75 m)
7 – 9 ft
(2.2 – 2.75 m)
7 – 9 ft
(2.2 – 2.75 m)
7 – 10 ft
(2.1 – 3.0 m)
7 – 10 ft
(2.1 – 3.0 m)
7 – 10 ft
(2.1 – 3.0 m)
7 – 10 ft
(2.1 – 3.0 m)
7 – 10 ft
(2.1 – 3.0 m)
Lookdown Zone
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Environment §
Standard Standard Difficult Difficult Difficult Difficult Standard Difficult Standard Difficult Difficult
Application
Smal to
Medium risk
Smal to
Medium risk
Medium risk
Smal to
Medium risk
Smal to
Medium risk
Smal to
Medium risk
Medium to
High risk
Medium to
High risk
High risk High risk
Narrow and
long areas
Blue Line Gen 2 Series Professional Series
§ Difficult environments include potential false alarm sources, such as rooms with:
• Air conditioning vents
• Strong drafts of cold or warm air
• Slow moving objects such as curtains, plants, or signs hanging from the ceiling
• A fan that could be running when the system is activated
• Underfloor heating
• Room temperatures exceed 86° F (30° C)
Or where the detector could be exposed to bright white light (car headlights, floodlights, direct sunlight etc.)