Operation
6 720 617 760 (2008/09)
The FR 10 can only regulate the heating system if an operating
mode is enabled. In conjunction with a time switch (accessory),
the time program automatically changes between the currently
selected operating mode / / and heating operation off .
Frost protection is safeguarded (Æ Chapter 5.6, page 23).
Controls
1
Rotary selector :
- Turn = Adjust value
- Press = Confirm setting/value
2Mode key:
- Change operating mode
- Accessing user level = hold down for approx. 3 seconds
- Accessing installer level = Hold down for approx. 6 seconds
- Return to the higher level
Symbols
Current room temperature or required room temperature
(if the rotary selector is turned)
Operating mode Comfort (factory setting is 21 °C)
Operating mode Economy (factory setting is 15 °C)
Operating mode Frost (factory setting is 5 °C)
No heating operation available, e.g. heating mode off due to time
switch (accessory) or boiler
Burner operation
Tab. 3
Set the central heating temperature controller on
the boiler to maximum, to allow the FR 10 to be ef-
fective.