CCTV | IP Network Video | Technical Brief | DIVAR IP 3000 Field Installation Guide | 5
Bosch Security Systems, Inc.
800.289.0096
www.boschsecurity.us
BVMS Configuration Client and Initial Device IP assignment
From the Kiosk interface select the BVMS
Configuration Client icon.
You will be prompted to log into Configuration Client
o User Name: Admin
o No Password
o The default loop back connection address of
127.0.0.1 should be present in the
connection drop down menu.
After logging into Configuration Client
o Select the “Hardware” menu option
o Select “Initial Device Scan…” sub menu
BVMS will perform a network scan for all defaulted
devices with the IP address of 192.168.0.1.
o Devices can individually be configured with
specific IP addresses based on MAC
address.
o To set all devices with random IP
assignment at once, select the “Select All”
tab
o Right click the highlighted devices and select
“SetIP Addresses…”
The “Set IP Addresses” menu should appear
o Enter the starting IP address for the address
range you are going to use
o Select the “Calculate” tab and the “End with”
section should auto populate
o SelectOK”
You should receive a message that the devices will
be restarted with the new IP addresses
o Select “OK”
o Close Configuration Client and return to the
Kiosk interface