Prior to installation
D
The exhaust air must not be removed
via a functioning smoke or exhaust-gas flue
or via a duct which is used to ventilate a
fireplace in the installation room.
Observe the official and statutory
regulations for the removal of exhaust air
(e.g. Landesbauordnungen)..
Removal of exhaust air via a
non-functioning smoke or exhaust-gas flue
requires the consent of a heating engineer.
D
If the extractor hood is operating in
exhaust-air mode at the same time as a
flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
there must be an adequate air supply
which the fireplace requires for combustion.
Safe operation is possible if the partial
vacuum in the installation room of the fire-
place does not exceed 4 Pa (0.04 mbar).
This can be achieved if the combustion air
is able to flow through non-lockable ope-
nings, e.g. in doors, windows and in con-
junction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.
If the air supply is inadequate, there is a
risk of poisoning caused by combustion
gases being drawn back into the room.
An air supply/air-intake wall box alone does
not ensure compliance with the limiting
value.
Note: When assessing the air supply,
always take into account the entire ventilati-
on system in the house. This rule does not
apply when using cooking appliances, e.g.
hob or gas cooker.
The fan must be attached at least 2 m
from the extractor hood.
Attach the inner wall fan inside the
building only, but not in living rooms.
When attaching the inner wall fan, ensu-
re that it is accessible for maintenance and
repairs.
The plug-and-socket connections of the
electric cables must be located inside the
building.
Do not reduce the 150 mm diameter of
the pipes connected to the extractor hood.
An additional silencer for 150 mm ø pipes is
available as an optional accessory from
specialist outlets.
Preparing the wall
The wall must be flat and perpendicular.
Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.
Weight: 7,3 kg.
We reserve the right to construction changes within the
context of technical development.