Bosch GLM 40 Use and Care Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
reference point can be changed
(see “Selecting the Reference
Point”, page 12).
Place the measuring tool with the
selected reference plane against
the desired starting point of the
measurement (e.g. a wall).
Briefly press the measuring
button 2 to switch on the laser
beam.
Aim the laser beam at the
target surface. Briefly press the
measuring button 2 again to
initate the measurement.
In the continuous measurement
mode, the measurement begins
immediately upon switching on
the function.
Typically, the measured value
appears after 0.5 seconds and
latest after 4 seconds. The
duration of the measurement
depends on the distance, the
light conditions and the reflection
properties of the target surface.
The laser beam is switched off
automatically upon completion of
the measurement.
When no measurement has
taken place approx. 20 seconds
after sighting, the laser beam
is switched off automatically to
save the batteries.
SELECTING A REFERENCE
POINT (see figure A)
For the measurement, you
can select between two
reference planes:
– The rear measuring-tool edge
(e.g. when measuring onward
from a wall),
– The front measuring-tool edge
(e.g. when measuring onward
from a table edge),
To select the reference
point, press button 6 until the
requested reference point is
indicated on the display. Each
time after switching on the
measuring tool, the rear edge of
the measuring tool is preset as
the reference point.
CHANGING THE UNIT OF
MEASURE
The unit of measure can be
changed any time for display of
the measured values, even for
already measured or calculated
values.
For display
of the current
length
measurement
values, the
units of
measure shown opposite are
available.
To change the unit of measure,
push button 3 until a new unit of
measure is displayed.
The unit-of-measure setting is
retained when switching the
measuring tool on or off.
-12-
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 51 52

Comments to this Manuals

No comments