4.3 Calibration
Calibration is only necessary if you want the speed and size of
detected objects to be interpreted correctly. You do not need
to perform this step if you do not want objects to be filtered on
the basis of these two properties.
In the calibration mode, a virtual horizontal plane is overlaid on
top of the camera image:
The virtual plane appears as a blue grille and can be tilted,
rotated and scaled. Position the virtual plane on the camera
image so that it matches the angle and perspective of one of
the actual horizontal areas.
Two red cubes are shown at opposite corners of the plane.
In the default setting, the side length of one of these cubes is
equivalent to 2 meters, so the cube is about the same height as
a person. The cubes are shown in the perspective of the blue
plane.
You can adjust the position and size of the cubes – so that a
cube corresponds to a car, for example.
A section of a street is a suitable reference area, especially if
the sides of the street are marked.
i
NOTE!
Display of measurements can be adjusted, so that when using
the English software interface imperial measurements are
shown. You will find additional information in Section 5 Display
of Measurements, page 38.