VSS7390/01T Switcher | Installation Manual | Chapter 2 EN | 10
2.4.8 Motion Sensitivity
Set motion alarm as follows:
1 Reset indicator.
2 Set level on minimum.
3 Walk through motion area (motion indicator indi-
cates level of motion).
4 Set level just below the level of motion indication.
2.4.9 Service
The SERVICE menu contains all items relevant for
servicing your observation system: resetting the system
to factory defaults and the internal diagnose.
2.4.10 Disable System Setting Option
You can disable the system setting option, ensuring
operators do not make inadvertent system changes.
To menu lock the system settings option:
Switch the complete system off.
Switch the system on while keeping the PIP and PIP
Swap buttons pressed at the same time. Continue to
keep the buttons pressed until the start-up screen
appears.
System settings are removed from the main menu.
Note
Follow the same procedure to unlock the system settings
menu.
FIELD OF
VIEW
(Range 1: 1.33: 1.66 : 2: default is
1). Adjust the field of view using
digital zoom in the camera to
ensure complete coverage of the
object within the viewing angle of
the camera lens.
MICROPHONE
Select the microphone ON/OFF.
This function will be disabled when
cameras are connected without a
microphone (e.g. covert cameras).
MOTION
AREA
Allows you to define the area size
for motion detection.
MOTION
SENSITIVITY
Allows you to define the sensitivity
of motion detection.
This enables you to detect objects
like a person running across the
motion area but will not raise an
alarm if there is a small movement
(detect humans but no birds).
DISPLAY
MOTION
This allows you to view where the
motion has been detected by dis-
playing a series of movement indi-
cators on the monitor screen.
MAIN MENU
SYSTEM SETTINGS
INSTALLATION
SETUP CAMERA 1
MOTION SENSITIVITY 1
LEVEL
MOTION INDICATOR
RESET INDICATOR
LEVEL Sets the level (the amount) of
motion detection.
MOTION
INDICATOR
Displays the set level of motion
detection.
RESET
INDICATOR
Resets the motion detection indica-
tor to the current setting.
MAIN MENU
SYSTEM SETTINGS
SERVICE
SYSTEM DIAGNOSE
FACTORY DEFAULTS
SYSTEM
DIAGNOSE
With this option you can obtain an
overview of the internal diagnose
settings. (Consult the service man-
ual for more information).
FACTORY
DEFAULTS
With this option you can set the
complete system to the factory
defaults. All current settings will be
lost, (this will take a few seconds).
Language selector and Wizard
setup will be activated again.
MAIN MENU
SYSTEM SETTINGS
SEVICE
FACTORY DEFAULTS
CURRENT SETTINGS
WILL BE LOST
CONTINUE?
NO YE S