5Operation
5.1 Switch on
Put the Power switch on the rear of the voice alarm
controller (see figure 5.1) in the I position.
If mains power or back-up power is available, the power
indicator on the front of the voice alarm controller is lit
(see figure 5.2). If the basic system contains a call
station, the power indicator of the call station is also lit
(see figure 2.5, no. 1).
5.2 Switch off
Put the Power switch of the voice alarm controller (see
figure 5.1) in the O position.
5.3 Calibration
Calibration is necessary for a correct loudspeaker line
impedance supervision (see section 4.5.5.3). To calibrate
the voice alarm controller, push the calibration switch
(see figure 2.3, no. 24). The system must be calibrated:
When the voice alarm controller is switched on for
the first time.
After the connected loudspeakers are changed.
After loudspeakers have been added.
After the settings of the connected loudspeakers have
been changed.
5.4 Background music
5.4.1 Introduction
The background music (BGM) is controlled using the
BGM controls on the front of the voice alarm controller
(see figure 2.3). Proceed as follows to route BGM:
1 Select the BGM source (see section 5.4.2).
2 Select the zones (see section 5.4.3).
5.4.2 Select BGM source
Select the BGM source with the Select button (see
figure 5.3). A green LED indicates the source that is
selected.
If the source is a CD player or a tuner that is
connected to the CD/Tuner input (see section 3.7),
choose CD/Tuner.
If the source is an auxiliary source that is connected
to the Aux input (see section 3.7), choose Aux.
Note
It is assumed that the APR mode switch (see
section 4.4) is in the OFF position.
figure 5.1: Power switch
figure 5.2: Power indicator
Note
When the system is switched on for the first
time and supervision is enabled, calibrate the
system (see section 5.3).
115 V ~
230V~
Apparatus delivered
Connected for 230V~
Power
Processor reset
Network
Call/EMG
Music/Spare
Ground short
Input
Mains
Battery
Zone1
Zone2
Zone3
Zone4
Zone5
Zone6
Fault Indicators
A
B
Disabled
Message
EMG mic
RCP
Router
0dB
-6dB
-20dB
figure 5.3: BGM source selector
0
-
+
-
+
CD/Tuner
Aux
Select
Zone select