D1260/D1260B | Owner's Manual | Part II: System Commands - WALK TEST ? (COMMAND + 4 + 4)
Bosch Security Systems | 9/04 | 50410D 25
4. Your system displays event summary lines and
point text in this order:
a. fire alarm summary line
b. point text for each fire alarm event
c. alarm summary line
d. point text for each alarm event
e. fire trouble summary line
f. point text for each fire trouble event
g. trouble summary line
h. point text for each trouble event.
5. Press NEXT> to scroll through the events.
If there are no events to view,
There are
currently no events in memory
displays.
6. You can return to idle text at any time by pressing
Exit> soft key.
WALK TEST ? (COMMAND + 4 + 4)
Walk Test
Description
Use this function to test keypads, detection devices,
and sounders (both interior and exterior) to be certain
they function properly. You can review untested points
at your keypad to help pinpoint any problems.
You cannot arm your system while in the walk test
mode, and no alarm reports are sent to your security
company unless a 24-hour point is activated (such as
fire or panic). A Walk Test Start Report may be
programmed to be sent to your security company.
Upon initiation, the walk test will test the burglary bell
pattern on the bell output and ring the keypad burglary
bell for 2 seconds. The AC will be disabled for 4
minutes in order to test the system’s battery power. If
the battery cannot maintain the system for the 4-minute
period, the keypad will appear to go dead. If your
keypads are programmed to be supervised, the main
alarm panel will beep intermittently during this 4-
minute period. If this happens, contact your security
company. At the end of the 4-minute period, AC is
returned to the system and the panel restores. To test
individual detection devices, simply activate sensors
and open protected doors and windows one-at-a-time.
As each detection device is faulted, the Keypad emits a
brief tone and the display indicates for 60 seconds that
the point has been tested. This verifies that each
detection device is working properly.
Using Walk Test:
1. The display shows disarmed idle text.
2. Press the COMMAND key. The display shows
*System Command*
.
3. Press the 4 key and then the 4 key.