3.2 Connecting via Serial port (VP-RS2BLNX Configuration Tool)
It is recommended that the CTFID software be installed before connecting the hardware to
the serial port. Refer to Section 2 Installing the CTFID Software, page 5 for additional
information.
To see the device output, use a CCTV monitor. Plug the coax connected to the imaging device
to one of the BNC connectors of the VP-RS2BLNX (which can operate in either RS-232 or RS-
485 mode). Connect another coax between the second BNC connector and the CCTV monitor.
Ensure that the monitor is either auto-terminating or is set to low impedance. See Figure 3.3
for an example of a typical CCTV monitor’s connections.
Figure 3.2 VP-RS2BLNX connections
Figure 3.3 Connecting the VP-RS2BLNX Configuration Tool
Number Description
1 Power and serial connection
2 Selects mode and baud rate
3 BNC connections, passive loop-through, high impedance, video input 1 Vpp nominal,
2Vpp max.
Number Description
1 Typical AutoDome version 5.10 or higher, and any other Bilinx device
2Coax IN
3 Terminal block
4VP-RS2BLNX
5 PC running CTFID software
6 RS-232
7 Power supply (not provided)
8Coax OUT
9 Typical CCTV monitor