Bosch VBN-5085-C11 Installation Manual Page 38

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 37
38 en | Configuration DINION 5000 AN
AM18-Q0644 | v1.0 | 2013.03 Installation Manual Bosch Security Systems
5.6.4 Alarm I/O submenu
Item Selection Description
Input None, high,
low
Select none to disable the alarm input.
Select active-high or active-low for the
alarm input connector.
Input action None,
Mode 1 to 6,
Night mode
Selects the operating mode of the
camera when the alarm input is active.
Output Normally
open,
Normally
closed
Selects the relay output mode.
Output action VMD,
Ext. device,
Night mode,
Filter toggle
VMD: - output relay closes on VMD
alarms.
External device: - make the output
relay available to remote
communication devices.
Night mode: - output relay closes when
camera is in monochrome mode.
Filter toggle: - output relay closes just
before the IR filter starts moving and
opens when video level has stabilized
(2 to 3 seconds)
EXIT Returns to Install menu.
Page view 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 51 52

Comments to this Manuals

No comments