Bosch X10 User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 132
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
VideoJet X10 Configuration Using a Web Browser | en 63
Bosch Security Systems Installation and Operating Manual V3.0 | 2007.09
5.22.4 Destination password
If the remote station is password protected, enter the password here.
In this page, you can save a maximum of ten destination IP addresses and hence up to ten
passwords for connecting to remote stations. If connections to more than ten remote stations
are to be possible, for example when initiating connections via higher-ranking systems such as
VIDOS or Bosch Video Management System, you can store a general password here. The
VideoJet X10 can use this general password to connect to all remote stations protected with
the same password. In this case, proceed as follows:
1. Select 10 from the Number of destination IP address list field.
2. Enter the address 0.0.0.0 in the Destination IP address field.
3. Enter your chosen password in the Destination password field.
4. Define this password as the user password for all remote stations to which a connection
is to be possible.
5.22.5 Video transmission
If the unit is operated behind a firewall, TCP (HTTP Port) should be selected as the transfer
protocol. For use in a local network, select UDP.
5.22.6 Remote port
Depending on the network configuration, select a browser port here. The ports for HTTPS
connections will be available only if the On option is selected in the SSL encryption
parameter.
5.22.7 Video output
If you know which unit is being used as the receiver, you can select the analog video output to
which the signal should be switched. If the destination unit is unknown, it is advisable to
select the First available option. In this case, the image is placed on the first free video
output. This is an output on which there is no signal. The connected monitor only displays
images when an alarm is triggered. If you select a particular video output and a split image is
set for this output on the receiver, you can also select from Decoder the decoder in the
receiver that is to be used to display the alarm image.
5.22.8 Decoder
Select a decoder of the receiver to display the alarm image. The decoder selected has an
impact on the position of the image in a split screen. For example, you can specify via a VIP XD
that the upper-right quadrant should be used to display the alarm image by selecting
decoder 2.
i
NOTICE!
If you enter the destination IP address 0.0.0.0 for destination 10, the VideoJet X10 will no
longer use this address for the tenth attempt at automatic connection in the event of an
alarm. The parameter is then used only to save the general password.
!
CAUTION!
Please note that in some circumstances, a larger bandwidth must be available on the network
for additional video images in the event of an alarm, in case Multicast operation is not
possible. To enable Multicast operation, select the UDP option for the Video transmission
parameter here and on the Network page (see Section 5.28.5 Video transmission, page 78).
i
NOTICE!
Refer to the destination unit documentation concerning image display options and available
video outputs.
Page view 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 131 132

Comments to this Manuals

No comments