114 en | Appendix VideoJet X40 SN
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
8.5 Processor Load
If the VideoJet X40 SN is accessed via the Web browser, you will see the processor load
indicators in the top right of the window next to the manufacturer's logo.
You can obtain additional information to help you when troubleshooting or fine tuning the
unit. The values indicate the proportions of the individual functions on the encoder load,
shown as percentages. The JPEG parameter relates to snapshots and M-JPEG. The scaler
converts the input format 4CIF to the other formats configured.
1. Move the cursor over one of the graphic indicators. Some additional numerical values are
also displayed.
2. Click one of the graphic indicators. Further details are displayed.
8.6 Network Connection
You can display information about the network connection. To do this, move the cursor over
the i icon.
8.7 Serial Interface
Options for using the serial interface include transferring transparent data, controlling
connected units or operating the unit with a terminal program.
The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The
mode used depends on the current configuration (see Section 5.37 Advanced Mode: COM1,
page 80). Connection is via the terminal block.
Link Ethernet link type
UL Uplink, speed of the outgoing data traffic
DL Downlink, speed of the incoming data traffic