84 en | Configuration Using a Web Browser VideoJet X40 SN
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
Force registration now
You can force the registration by transferring the IP address to the DynDNS server. Entries
that change frequently are not provided in the Domain Name System. It is a good idea to force
the registration when you are setting up the device for the first time. Only use this function
when necessary and no more than once a day, to avoid the possibility of being blocked by the
service provider. To transfer the IP address of the VideoJet X40 SN, click the Register button.
Status
The status of the DynDNS function is displayed here for information purposes. You cannot
change any of these settings.
5.39 Advanced Mode: Advanced
The settings on this page are used to implement advanced settings for the network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The VideoJet X40 SN is rebooted and the changed
settings are activated.
SNMP
The VideoJet X40 SN supports the SNMP V2 (Simple Network Management Protocol) for
managing and monitoring network components, and can send SNMP messages (traps) to IP
addresses. The unit supports SNMP MIB II in the unified code. If you wish to send SNMP
traps, enter the IP addresses of one or two required target devices here.
If you select On for the SNMP parameter and do not enter an SNMP host address, the
VideoJet X40 SN does not send them automatically, but only replies to SNMP requests. If you