Page view 11
5C) Four Wire Flexible Conduit Con-
nection
Note: DO NOT plug in range at this time.
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the terminal block.
3. Remove the top nut, star washer, and round washer from each post.
Note: DO NOT remove last round washer, last nut or internal wire leads.
4. Remove screw from bottom end of ground strap.
5. Remove ground strap from center post. Discard.
6. Attach one terminal lug (packaged with this manual) through hole below termi-
nal block with ground screw.
7. Place one terminal lug (packaged with this manual) on each post. Replace the
star washer and round washer and secure with 20 inch pounds of torque.
8. Strip 3/8 (9.53 mm) inches of insulation from the end of the wire.
3/8 "
Figure 12: Wire Stripping
9. Insert the insulated grounding wire into the lug below the terminal block.
10. Insert stripped end of white wire into the center lug. Secure the clamping-
screw.
..J'j
lug . __2'
wire
clamping screw
Figure 13: Attaching Wire to Lug
11. Insert stripped end of red wire into the left lug. Secure clamping screw.
12. Insert black wire into the right lug. Secure clamping screw.
13. Tighten each clamping screw with the appropriate torque (see table).
Table 2: Appropriate Torque Levels for Aluminum or Copper Wire
6 35 3.95