8/14 Bosch Rexroth AG Hydraulics 3FREEZ RE 29221/08.05
Connection
For electrical data, see page 7 and
Operating Instructions 1 819 929 083
Technical notes for the cable
Design:Multi-wire cable
– Extra-finely stranded wire
to VDE 0295, Class 6
– Safety earth conductor, green/yellow
– Cu braided shield
Type: – e.g. Ölflex-FD 855 CP
(from Lappkabel company)
No. of wires: – Determined by type of valve,
plug type and signal assignment
Cable Ø:0.75 mm
2
up to 20 m long
1.0 mm
2
up to 40 m long
Outside Ø:9.4...11.8 mm – Pg 11
– 12.7...13.5 mm – Pg 16
Important
Power supply 24 V DC nom.,
if voltage drops below 18 V DC, rapid shutdown resembling
“Enable OFF” takes place internally.
In addition, with the “mA signal” version:
I
D-E
3 mA – valve is active
I
D-E
2 mA – valve is deactivated.
Electrical signals (e.g. actual values) emitted via the trigger
electronics must not be used to shut down safety-relevant
machine functions!
(Also see European Standard, “Technical Safety Requirements
for Fluid-Powered Systems and Components – Hydraulics”,
EN 982).