Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Bosch Sensortec
AN18002
Rev. 1.0
Page 32
© Bosch Sensortec GmbH reserves all ri
hts even in the event of industrial propert
ri
hts. We reserve all ri
hts of disposal such
cop
in
and passin
onto third parties.
7211RB11.
Settings Æ Display PROM Data
For some basic evaluation purposes, there is the possibility to display the stored SMD500
PROM data.
1. Open Settings Æ Display PROM data
2.
The following message box appears
3.
It is possible to manually view the stored data:
• AC1 to AC6 are the calibration coefficients expressed as raw data
o varying form 9 to 14 bit words
• F1 to F4 are shifted calibration coefficients
o shifted to generate 4 uniform 16 bit words containing the 6 AC
coefficients
Comments to this Manuals