Page view 0
WARNING
: Improper installation,
adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For
assistance or additional information consult a qualified
installer, service agency or the gas supplier.
Upon completion of the installation, these instructions
should be handed to the user of the appliance for future
reference.
In the Commonwealth of Massachusetts this product
must be installed by a licensed plumber or gas fitter.
INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC
INSTANTANEOUS TYPE WATER HEATERS FOR USE WITH NATURAL AND
LIQUEFIED PETROLEUM GAS
MODEL 38B LP and NG
Suitable for heating potable water only
Not approved for space heating purposes
Intended for low flow domestic hot water applications with steady cold water inlet temperatures
WARNING
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable,
combustible or corrosive vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any
phone in your building.
- Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Specifications.................................................................Page 2
Rules for safe operation ............................................... Page 4
Locating the Heater ......................................................Page 4
Combustion Air Requirements ....................................Page 5
Mounting the Heater .....................................................Page 5
Venting the Heater ........................................................ Page 7
Gas Connections .......................................................... Page 9
Water Connections .................................................... Page 10
Safety before lighting the pilot ................................ Page 11
Lighting instructions ................................................... Page 11
Setting water temperature ........................................ Page 12
Maintenance & Service ............................................. Page 12
Trouble Shooting ......................................................... Page 13
Diagram of AquaStar ................................................. Page 16
Components and Parts List ...................................... Page 19
Warranty ....................................................................... Page 21
TABLE OF CONTENTS
6 720 606 446 US (06.01) AL
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - TABLE OF CONTENTS

WARNING: Improper installation,adjustment, alteration, service or maintenance can causeinjury or property damage. Refer to this manual. Forassistanc

Page 2 - UNPACKING THE AQUASTAR HEATER

10 6 720 606 446Connecting the pressure relief valve (PRV)A listed pressure relief valve supplied with the heater mustbe installed at the time of inst

Page 3 - NON COMBUSTIBLE MATERIALS

116 720 606 446LIGHTING INSTRUCTIONS (as seen on front coverof heater)1. STOP! Read the safety information on the front panel ofthe heater.2. The Gas

Page 4 - FOR SAFE OPERATION

12 6 720 606 446Fig. 6 - Water Flow Control KnobThe position you select on the temperature adjustment knobwill depend on the temperature of the incomi

Page 5 - MOUNTING INSTALLATION

136 720 606 446PILOT DOES NOT LIGHT1. No gas to the AquastarA. Gas cock on gas line may not be open.B. Gas valve button has not been moved to “PILOTPO

Page 6

14 6 720 606 446BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNEDON1. Pilot is not on.Light the pilot. See lighting instructions.2. Pilot lighting push b

Page 7 - Figure A Figure B

156 720 606 4464. Btu input is too low due to insufficient gas supplyMake sure your main gas line is fully opened. If using LPgas, be sure that the si

Page 8 - MASONRY CHIMNEYS

16 6 720 606 446Fig. 9 - Diagram of AquaStar 38 B 2 4 810 17911 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gaspressure test nipple 4

Page 10 - WATER CONNECTIONS

18 6 720 606 446Fig. 10 - INTERIOR COMPONENTS DIAGRAM AND PARTS LIST

Page 11 - THE PILOT

196 720 606 446Fig. 10INTERIOR COMPONENTS DIAGRAMAND PARTS LIST 38B1 Cover 8 705 421 0212 Temperature adjustment knob 8 702 000 1824 Draft dive

Page 12 - SETTING THE WATER TEMPERATURE

2 6 720 606 446This well engineered, gas water heater has all the fea-tures a water heater should have:It operates on the principle of heating water i

Page 13 - PILOT DOES NOT LIGHT

20 6 720 606 446Fig. 11 - Flow chart of Aquastar 38 B

Page 14 - 14 6 720 606 446

216 720 606 446LIMITED WARRANTYAquastarGeneralAquastar water heaters are warranted by the Manufacturer(BOSCH) through BBT North America. BBT North Ame

Page 17 - 176 720 606 446

Bosch HeatingSystem Co. Foschan GuangdongC. T. 528315 P.R. ChinaRecycled paper31&21segapeesELBATECNANETNIAMRAEYYREVESRAEY2YREVESRAEY5-3YREVEEVLAVR

Page 18 - 18 6 720 606 446

36 720 606 446MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE ANDNON COMBUSTIBLE MATERIALSFRONT VIEWSIDE VIEWAQUASTAR MODEL 38BMODEL 38BTOP (A) 12 &q

Page 19 - AND PARTS LIST 38B

4 6 720 606 446GENERAL RULES TO FOLLOWFOR SAFE OPERATION1. You should follow these instructions when you install yourheater. In the United States: Th

Page 20 - 20 6 720 606 446

56 720 606 446COMBUSTION AIR REQUIREMENTThe AquaStar water heater holds cold water in its copperheat exchanger and brass water valve when not in use.B

Page 21 - LIMITED WARRANTY

6 6 720 606 446Appliances located in unconfined spaces:a) An unconfined space is one whose volume is greaterthan 50 cubic feet per 1000 Btu per hour o

Page 22 - 22 6 720 606 446

76 720 606 446VENTINGVent pipe connection. WARNING: Do not reduce the vent pipe size.The heater must be vented to the outside following all local ord

Page 23 - 236 720 606 446

8 6 720 606 446MASONRY CHIMNEY: Masonry chimneys shall be built and installed in accordance with NFPS 211 or local codes. Aminimum 4” diameter gas ve

Page 24 - Bosch Heating

96 720 606 446WARNINGNote: The burners of an instantaneous “on demand” waterheater such as the AquaStar are only on at the time thathot water is actua