" (continued) PLAN THE DUCTWORK
Note: the high leve! of air flow of this appliance may effect the gas
flame on some types of gas cooktops. This is NORMAL and wil!
cause no harm, but can be corrected by lowering the speed of the
blower.
RIGHT
DISCHARGE
VOLTS AMPS CFM DUCT
Approx.
120 4.0 600 3ol/4 x 10
TAKE MEASUREMENTS
Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The
Model DHD865AUC will fit in most 30" wide cabinets and the
Model DHD965AUC will fit in most 36" wide cabinets. How-
ever, it is recommended that oversized cabinets be used for
easier installation.
Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that Io3/4" is necessary between the back edge of the
cooktop and the inside of cabinet back.
1,
2,
LEFT
DISCHARGE
'_ DOWN
DISCHARGE
(as shipped)
This downdraft blower system is designed for use with 3ol/4"
x 10" ductwork (can be transitioned to 6" round). Three
different discharge directions are available with side-to-side
adjustment for accurate alignment of ductwork.
For best performance: Choose the duct!rig option which allows
the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
NOTE: The unit is shipped with the 3ol/4" x 10" discharge
facing DOWN. See "CHANGING BLOWER DIRECTION" on
page 3, if necessary.
6"ROUND _[S-1/4"X 10"
ELBOW_ "IT06" RD.
TRANSITIO
|EQUALS2L I/'I
EQUALS6 FT.OF _FT.OF "_
STRAIGHTDUCT ,,[STRAIGHTDUCT
01 4ELxol,O"
EQUALS8_
IFT, OF
[STRAIGHTDUCT
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation,
PLAN THE WIRING
1,
2,
The downdraft blower system draws 4 AMPS and requires a
120 VAC, 60 Hz circuit.
The unit has a 2 ft. long power cord with a 3-pronged plug. Plan
to provide a grounded outlet in a location which will allow the
unit's power cord to reach. (Note: If the Model DHD865AUC is
being installed in a 30" wide cabinet orthe Model DHD965AUC
is being installed in a 36" wide cabinet, the outlet cannot be
located on the back wal! of cabinet.) Outlet may also be wallo
mounted, with access hole in cabinet.