LTC 9384 Series | Instruction Manual | Installation
EN
|
12
Bosch Security Systems | September 1, 2004
For 24 Volt Cameras:
1. Installing a 24 volt camera into the LTC 9384/50
housing uses the internal transformer for camera
power (see FIGURE 11).
2. Connect the supply (230VAC) to the terminal
block. Use only the terminal block provided for
this connection.
3. Connect the secondary flying leads to the camera's
24 volt input. Refer to the wiring diagram for
clarification.
FIGURE 11 LTC 9384/50 Transformer Wired for
24 Volt Camera
5.7 Video Coax Connection
WARNING: Use only the cables specified
under INSTALLATION, Cable Requirements
for video coax wiring connection.
If no lens control or feed-through wires will be used:
1. Install the seal cap portion of the large liquid-
tight fitting on the video coax cable, and pull
the cable through the right-hand fitting on the
rear of the cradle. If lens control is used, pull
the cable through the small bottom fitting.
2. Attach the BNC connector to the coax and
connect it to the camera. Pull any excess wire
out of the cradle assembly and tighten
approximately 1 to 11⁄2 turns past the point
where the fitting starts to grip the wire. Failure
to do so will result in water damage to all
electronic parts. Use a tie wrap (included) to
provide strain relief on the video cable at the
exit point (inside the unit).
3. Install the 3⁄8in. NPT plug provided in the
unused, small top center NPT hole.
Securely tighten all fittings to ensure a liquid-
tight seal. Failure to do so could allow water to
enter the housing and damage the camera and
lens.
5.8 Lens Wiring
WARNING: Use only the cables specified
under INSTALLATION, Cable Requirements
for video coax wiring connection.
1. If installing a zoom lens, insert the lens
control cable with the installed seal cap in
through the right fitting at the rear of the
cradle. Attach the lens wiring to the lens
mating connector and connect it to the lens. If
the mating connector is not available, connect
directly to the lens cable.
NOTE: See the specification on lens cord for
the correct plug connection.
Securely tighten all fittings to ensure a liquid-
tight seal. Failure to do so could allow water to
enter the housing and damage the camera and
lens.
2. If using a pan/tilt with a feed-through cable,
insert the camera/lens function cable in
through the right-hand fitting at the rear of the
cradle. Wire the functions as described above
or as needed.
Use of drip loops is not recommended on the
wiring outside of the rear endcap.
5.9 Final Assembly
5.9.1 Pull Seal Installation
If the breather hole is open, do NOT mount the
housing in a position where the front endcap is
pointed upward.
To maintain enclosure protection ratings of NEMA-6P
and IP68, the pull seal (provided in the hardware kit)
must be installed in the front endcap. Install the pull seal
in a cool, dry environment to prevent trapping moisture
inside the housing (see FIGURE 12).
NOTE: Pull seal installation allows the housing's front
endcap to be pointed upward.
Brown
Red
To Camera
Blue
Red
24 VAC
230 VAC
Input
White/
Black
Striped
White/
Black
Striped
6
5
1
2
12
11
8
7
To Heater/Defogger
To Heater/Defogger