Intrusion Alarm Systems | B4512 Control Panels
B4512 Control Panels
www.boschsecurity.com
u Supports up to 28 points using a combination of
hardwired or wireless points for installation
flexibility and 2 areas with perimeter and interior
control
u On-board Ethernet port for Conettix IP alarm
communication and remote programming,
compatible with modern IP networks including IPv6/
IPv4, Auto-IP and Universal Plug and Play
u Installer-friendly features including on-board USB
for easy on-site RPS programming, plus plug-in
PSTN and Cellular communication modules for
simple installation and future proof upgrades
u Notifications with email and text messaging, and the
Remote Security Control app for Android and iOS
mobile devices
u Programmable keypad shortcuts, situation sensitive
on-screen help, and a bilingual user interface make
system operation simple and easy
The B4512 Control Panel integrates intrusion and
residential fire, providing one simple user interface for
both systems. The B4512 provides up to 28
individually identified points that can be split into 2
areas. The control panel includes a built-in Ethernet
port for IP network communications, and is
compatible with modules that send events to selected
public switched telephone network (PSTN), IP
network, or cellular network destinations through four
programmable route groups.
With the B4512, you can monitor doors, windows, and
motion within areas like showrooms or those that hold
inventory. Each user can have a personalized
passcode, a wireless keyfob, and a credential to
control the system.
Use programmable authority levels with restricted
privileges to provide service, security, and cleaning
personnel with full or limited access. Use the three
programmable outputs (expandable up to 27) to turn
on lights or open and lock doors. Users can:
Turn on the system to secure the stock room while
you conduct daily business.
Perform tests to ensure your system is working
properly.
Set your system to alarm immediately if a door opens.
Activate the Watch feature so a tone sounds
whenever a customer enters.
Set a schedule for your system to automatically turn
on at closing time.
Use wireless security options to customize your
system.
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - B4512 Control Panels

Intrusion Alarm Systems | B4512 Control PanelsB4512 Control Panels www.boschsecurity.com u Supports up to 28 points using a combination o

Page 2

Central monitoring stations provide 24-hour systemmonitoring with access to vital services. Professionalsecurity personnel can test the system, monito

Page 3

System usersThe system supports up to 32 users. Each user canhave a personalized passcode, a wireless keyfob, and acredential to control the system. U

Page 4

The log stores up to 127 local and reported events.Scheduled events (SKEDs)The internal clock and calendar start individuallyscheduled events (SKEDs).

Page 5 - 5

FCC-380 Carbon Monoxide DetectorBosch conventional detectors, including Professional Series, Blue LineGen2, Blue Line, Classic Line, Commercial Line,

Page 6

EN4200 Serial ReceiverEN5040-T High Power Repeater with TransformerParts includedThe B4512 includes the following:Quant. Component1 B4512 board1 Liter

Page 7 - 7

7 | B4512 Control PanelsRepresented by:Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:Bosch Security Systems, Inc.130 Peri

Comments to this Manuals

No comments