Bosch BOVA-36HN1-M18M User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Installation Instructions Bosch IDS BOVA | 15
Bosch Thermotechnology Corp. | 12.2016
Data subject to change
11 Electrical - low voltage
11.1 Low Voltage Maximum Wire Length
Table 3 defi nes the maximum total length of low voltage wiring from the outdoor unit,
to the indoor unit, and to the thermostat.
24 Volts - Wire size Max. wire length
18 AWG 150 Ft.
16 AWG 225 Ft.
14 AWG 300 Ft.
Table 3
11.2 Low voltage hook-up diagrams
Air Handler Hook-up Diagram
Low Voltage connection
must be made inside the
outdoor unit case.
Access
Panel
Figure 25
THERMOSTAT
C
INDOOR UNIT
OUTDOOR UNIT
Y
R
G
Y
B
L
A
CK
G
C
C
B
R
B
Control Wiring for H/P Systems.
W2
D/W
w1
Notes:
1. Be sure power supply agrees with
equipment nameplate.
2. Power wiring and grounding of
equipment must comply with local codes.
3. Low voltage wiring to be No. 18 AWG
minimum conductor.
4. “____” The electric auxiliary heat
connection.
Figure 26
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 43 44

Comments to this Manuals

No comments