Thermostat Wire Connections | 11SM Series Electric Heat
8 733 904 449 (2013/04)SM Series Electric Heat
20. Use push in wire ties to secure cables to cover
and blower bracket.(Figure#34)
Figure # 34
THERMOSTAT WIRE CONNECTIONS
1. Assure that two low voltage wires are available
from the thermostat to make the “W1” and
“EM” connections. If these wires are not
located, they will need to be pulled and routed
from the back of the thermostat to main
thermostat connections on the electrical box
or to the motor control board.
2. Strip the insulation off of the “W1” and “EM”
wires and insert into the thermostat control
wire block or on the motor control board
thermostat interface. Connect the other end of
the wires to the back of the thermostat to the
supplemental and emergency heat terminals.
Reference the Thermostat User’s Manual for
proper connection.
Figure # 35
SITE LINE VOLTAGE CONNECTION
Routing New Line Voltage Wires
From Circuit Breaker Panel To Heater
Electrical Box
1. Select the proper wire size based upon the
heater electrical load that the blower motor
and electric heater element(s) will require.
Refer to the data tag label that is included in
the heater kit or the electrical data at the end
of this manual. Ensure that all national and
local electrical codes are followed for
installation, wire sizing, and breaker sizing.
2. Select the proper breaker size based upon the
heater electrical load that the heat pump will
require. Refer to the data tag label that is
included in the heater kit or the electrical data
at the end of this manual.
3. Route the new line voltage wiring and the
ground wire from the circuit breaker panel to
the heat pump.
4. Use the knockout provided in the heat pump
corner post as the entry for the electrical
service wiring. A plastic bushing should be
used to protect the wire insulation from the
metal edge of the knockout
5. Connect one of the line voltage wires to “L1”
terminal connection and the other line voltage
wire to “L2” terminal connection. Torque to 22
in-lbs.
6. Use the ground lug provided in the heater
control box to connect the field ground from
the power supply.