Page view 4
Installation - Hardware | 5SM Series Electric Heat
8 733 904 449 (2013/04)SM Series Electric Heat
Figure # 6
[1] Heating element cover
[2] Electric Heat control box
INSTALLATION - HARDWARE
1. At Thermostat Turn system to “OFF”
2. Turn the main power to the heat pump to
“OFF” at the unit’s disconnect switch or
breaker panel.
3. Prior to removing the blower panel, disconnect
unit display from the back of the
panel.(Figure#7)
Figure # 7
4. Remove the access panel(s) from the unit
exposing the blower section and compressor
section of the packaged heat pump unit.
5. Remove the heater collar cover plate(s).
(Figure#8)
Figure # 8
6. In preparation for heater element installation
orient the heating elements with thermal
overloads (cutouts) are on the right side for VT
& CF and top for HZ.(Figure#9)
Figure # 9
7. Insert heating element(s) into collar. Heating
element rods must be inserted into inner most
holes as shown in Figure#10. This will support and
prevent vibration of heater elements.
Follow proper lockout/tag out procedure.
Proper Thermal Overloads (cutouts)
orientation is required for safe unit
operation.
SM060 and SM070 models will have an
additional extension bracket mounted on
each cover plate. Heating element rods
must be aligned to extension brackets
accordingly.