GV4 Series Control Panel | Release Notes
4 Bosch Security Systems, Inc. | 11/11 | F01U261045-01
Cycl
e Relay, Cycle Door (Door Access and
Control), and Auto Re-arm.
Dual Authentication
Dual authentication requ
ires a user to present
both a credential to a D9210C door
controller, and a passcode to be entered at
an associated keypad.
Dual authentication requires the passcode
and credential of the same user to be
presented within the time duration set in
Command Center>Dual Authentication
Duration.
Arm/Disarm
The Arm/Disarm function changes a
ll
authorized areas in scope from disarm to
master armed, or from any armed state to
disarmed when Passcode and [ENT] is
pressed.
The control panel shall only arm areas where
the user has L# Passcode Arm authority
enabled and shall only disarm areas where
the user has L# Passcode Disarm authority.
Cycle Relay
The Cycles Relay comm
and momentarily
activates a preconfigured output when
Passcode and [ENT] are pressed.
A user
must have a non-zero authority level in
the keypads current area to perform the Cycle
Relay Function.
Cycle Door (Door Access and Control)
The Cycle D
oor Command was enhanced to
perform all functions associated with Door
Access. After a user is authenticated, the door
cycles the striker, the current area disarms,
and then a custom function executes.
Auto Re-arm Features
The Auto
Re-arm function is intended to be
used on a keypad with area-wide scope to
provide a facility with the ability to
temporarily disarm the perimeter before
automatically re-arming.
This keypad is assigned to an area that
contains a perimeter delay point. The user
can exit the facility through this point.
The Auto-Re-arm function automatically
restarts the exit delay for Master Arm if the
authenticating user has L# Passcode Arm
authority and the keypads current area is
already armed at any state.
2.1.4 Number of Users
Previous G
Series control panels delivered
249 passcodes and 996 credentials using a
User and Sub-User method. GV4 Series
control panels support a total of 1000 unique
users, whereby ì User 0î is the installer. Each
system user now supports a Passcode,
Credential, and Keyfob so that user activity is
unique and detailed.
The D9412GV4 can support up to 1000 users.
The D7412GV4 can support up to 400 users.
The D7212GV4 can support up to 100 users.
Standard Users are numbered from 1 to 999.
Any control panel user can be configured via
the keypad using Command 5-6, or through
the use of RPS.
All standard D9412GV4 and D7412GV4 users
can have an access credentials assigned with
individual authority permissions. Sub-Users
are not supported.
All standard users can be assigned a wireless
keyfob through RF Diagnostics or Command
56 on a keypad or through RPS.
If RPS is used to add, replace, or remove
any keyfobs, no keyfob-specific events will
be generated. Only the Parameters
Changed event will be logged.
2.1.5 SDI2 Support
The GV4 series control panel support two
independent SDI busses on the main control
panel. The SDI2 bus does not support SDI
devices.
SDI2 Module Supervision
When a
n SDI2 device fails supervision, a
system fault is annunciated at the keypads
indicating the individual device number.
When a SDI2 bus Octo-input module, or an RF
Receiver module is declared missing, then all
points associated with those devices will also
be declared missing.
SDI2 Module Tamper
Most S
DI2 bus devices have an optional
tamper input to detect when the cover is
opened or when the device is removed from
its mount.
Module tamper conditions reported by SDI2
bus modules will be annunciated on the
keypads as a system fault and optionally sent
to the central station as an event.