Fire System | User’s Guide | 7.0 Status LEDs
Bosch Security Systems, Inc. | 8/06 | F01U011793B 21
6.7 Non-Fire Trouble Events
You can program your keypad to emit a repeated pattern of
three warble tones, followed by a pause when a trouble
event, such as an AC failure, occurs.
The keypad display shows the number of non-fire trouble
(A1 ## TROUBLES), then custom text for each activated
point.
Silencing Non-Fire Trouble Events
To silence a non-fire trouble:
• On the D1255RB Keypad, enter a personal passcode and
press [ENT].
• On the D1256RB Keypad, press [TROUBLE SILENCE].
To clear the trouble message from the display, enter
[COMMAND] [4]. To review cleared troubles, use [NEXT]
and [PREV] or the VIEW MEMORY ? function.
7.0 Status LEDs
Four LEDs provide a quick indication of the fire system
status.
Table 1: Status LEDs
LED Activates: Turns off when:
Fire
• When fire alarm
condition exists.
• All fire alarm points
return to normal.
Silenced
• After an alarm condition
is silenced.
• [ANNUNCIATOR
RESET] key is pressed.
Supervisory
• When any point
programmed as
supervisory is
not normal.
• All supervisory points
that are not normal
return to normal.
Trouble
• When any system
trouble or point trouble
exists.
• The system and all
points return to normal.