GV2 Series Control Panels | Owner's Manual Supplement
24 Bosch Security Systems, Inc. | 2/07 | F01U063791-01
3. The user does not return to stop Entry Delay. The Entry Delay
time expires.
4. The control panel starts the alarm transmission sequence,
accompanied by an Exit Error report.
3.3.5 Master Arm No Exit Feature (Unvacated Premises)
If a user Master Arms an area and does not leave the premises (no
Entry/Exit zones are faulted during the exit time), the control
panel’s No Exit feature automatically shifts the Area from Master
Armed to Perimeter Armed.
I have this feature.
I do not have this feature.
3.3.6 Recent Closing
If an alarm occurs within two min of the expiration of Exit Time,
the control panel creates an “alarm-recent closing” event. If the
user armed with a passcode, the user number is included in the
recent closing report.
Recent Closing events are not created for Fire Alarm events.
3.4 User-Caused False Alarms, Disarming the
System
3.4.1 Entry Time Defaults
The SIA standard requires an Entry Time of between 30 sec and
4 min. The required default is 30 sec. If the system is not
disarmed within Entry Time, the control panel creates an Alarm
Event.
During the Entry Time, the control panel sounds an Entry Delay
Tone (distinct from the alarm tone).
3.4.2 Passcode Disarms System (Area)
When the control panel is in Entry Delay, entering a valid passcode
disarms the system as soon as the last digit of the passcode is
entered. No other keys are required.
When the control panel is in Exit Delay or is armed, entry of a valid
Passcode must be followed by an [ENTER] or [ENT] key.