Bosch ICP-CC404 Installation Guide Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 98
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
ICP-CC404 | Installation Guide | 6.0 System Functions
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 27
If horn speaker indication beeps are enabled, one
beep sounds from the horn speaker. If strobe
indications are enabled, the strobe flashes for 3 sec to
indicate the system is disarmed.
5.5.5 Panic Alarm
Press and hold both [AWAY] and [STAY] together
for 2 sec.
An audible Panic Alarm is initiated that activates the
horn speaker, strobe, and internal sirens.
If Option 1 is selected in Location 425
(refer to Section 18.2 System Options 2
on page 73), the remote radio Panic
Alarm is also silent.
5.5.6 Remote Outputs
The [DOOR] and [AUX] buttons on the four-channel
hand-held transmitter can operate two remote
outputs. Only the installer can program these outputs.
You can use the Output Event Types listed in
Table 18. Refer Section 16.0 Programmable Outputs for
more information.
Table 18: Remote Output Event Types
Output
Event Type Description Page
2,11 Radio Control Output 1 67
2,12 Radio Control Output 2 67
2,13 Radio Control Output 1 – not
armed in AWAY Mode
68
2,14 Radio Control Output 2 – not
armed in AWAY Mode
68
To turn Output 1 on:
Press and hold [DOOR] for 2 sec.
Output 1 turns on.
To turn Output 1 off:
Press and hold [DOOR] for 2 sec.
Output 1 turns off.
To turn Output 2 on:
Press and hold [AUX] for 2 sec.
Output 2 turns on.
To turn Output 2 off:
Press and hold [AUX] for 2 sec.
Output 2 turns off.
All reset times for the [DOOR] and
[AUX] buttons are referenced to
Polarities 1 and 8. Reset times vary
depending on the polarity used.
6.0 System Functions
This section explains more advanced features, such as
Installer Code, Master Code, and hold-down
functions used for testing and regular maintenance of
the system.
6.1 Installer Code Functions
Installer Code functions allow the installer to perform
various system tests and tasks without knowing a
Master Code.
To access the required Installer Code function, enter
the Installer Code and corresponding function digit,
and press [AWAY]. The Installer Code functions are
listed in Table 19.
You can only access these functions when the system
is disarmed.
Table 19: Installer Code Functions
Function Description
0 Reserved
1 Set the number of days until the first Test
Report
(Section 6.1.1)
2 Change domestic telephone numbers
(Section 6.1.2)
3 Change the Telco arming or disarming
sequence
(Section 6.1.3 on page 28)
4 Setting STAY Mode 2 zones
(Section 6.1.4 on page 30)
5 Satellite Siren (EDMSAT) Service Mode
(Section 6.1.5 on page 30)
6 Turn Telephone Monitor Mode on and off
(Section 6.1.6 on page 31)
7 Walk Test Mode
(Section 6.1.7 on page 31)
8 Event Memory Recall Mode
(Section 6.1.8 on page 31)
9 Reserved
6.1.1 Set the Number of Days until the First Test
Report
This function determines when the system sends the
first Test Report (Contact ID Event Code 602). If you
do not use this Installer Code Function, the first Test
Report is sent to the base station receiver after the
repeat interval programmed in Location 366 (refer to
Section 15.21 Test Reporting Time on page 63). If you
want the system to send the first Test Report sooner
than the repeat interval, use this function to set when
the first Test Report is sent.