Bosch LTC 5136/61 Instruction Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
LTC 5136 Series |
Instruction Manual
| Unpacking
EN
|
6
1 UNPACKING
This
electronic equipment
should be
unpacked and
handled
carefully
.
Check for the
following items:
LTC
5136/61
or LTC
5136
/
51
D
esktop
C
ontroller
.
Interface unit.
Power
supply
.
Power supply
cable.
One (1) 3 m (10 ft) cable with two (2)
R
J-1
1
connectors.
If an item appears to have been
damaged
in
shipment,
replace it
properly
in its carton and notify the
shipper
.
If any items are
missing,
notify your Bosch
S
ecurity
Systems,
Inc. Sales
Representative
or
Customer
S
ervice.
The
shipping
carton is the safest
container
in which
the
unit may be
transported.
Save it for possible future
use.
2 SERVICE
3 DESCRIPTION
The LTC 5136 Series
Controllers
are
designed
for
use
with the Bosch
AutoDome
Series
cameras.
They
can
also be used to operate any of the
conventional
Allegiant®
Series of
Receiver/
Drivers.
The LTC 5136 Series
controllers
support control of
all
AutoDome
and
Allegiant receiver/driver functions
including variable
speed
pan/tilt/zoom, pre-positions,
auxiliaries,
etc.
Typically,
one of the 16 outputs of
the
LTC 5136 junction box is
connected
to a
single
AutoDome
camera or
receiver/driver.
If the
application
will use a daisy
c
hain
wiring configuration,
up to
eight
(8) camera sites can be
controlled
from each of the
16
biphase
outputs.
The biphase control code cable can extend
a
maximum distance
of 1.5 km (5000 ft),
using
1.0 mm
2
(18 AWG) shielded
twisted
pair
cable
(Belden 8760 or
equivalent
).
3.1
P
ower
The model number and
operating voltage
are
shown
on the product
label.
If the unit ever needs repair service, the customer should
contact the nearest Bosch Security Systems, Inc. Service
Center for authorization to return and shipping
instructions.
Service Cent
ers
U.S.A.: Phone:
800-366-2283
or
408
-
956-3895
fax:
800-366-1329
or
40
8-
956
-
3896
e-mail:
N
ationalS
erviceC
.com
Canada:
514-738-2434
Europe, Middle East & Asia Pacific
R
egion:
3
2-1-
44
0-0
711
For
additional information,
see
www
.bosc
hsecuritysystems.com.
NOTE: Grounded wrist straps must be worn
and
proper ESD safety
precautions observed when
handling
the
electrostatic-sensitive
printed
circuit
boards.
Voltage Power
at
Model No
.
Rated Voltage Range Rated
V
olt
age
LTC 5136/51 230
VAC,
50/60 Hz 195.5 to 253 6
W
LTC 5136/61 120
VAC,
50/60 Hz 105 to 132 6
W
Page view 5