Bosch Solution 16plus Specifications Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
Basic Pager Reporting
This feature is only applicable if your system is reporting to a pocket pager. Basic pager
reporting requires some interpretation of the numbers that appear of the display. However, it
is possible to differentiate between 1000 different systems when a number of control panels
are reporting to the one pocket pager.
Basic Pager Display Information
Subscriber ID Number
This is the identification number of the control panel and can only be programmed by your
installer.
Zone Status
The zone status display shows you the status of each zone (1 – 8). The following table
describes what each number means when displayed on the zone status display.
Number
Displayed
Zone
Description
0
Zone Normal
This indicates that the corresponding zone is in the sealed state.
1
Alarm
This indicates that the corresponding zone is unsealed and in alarm
condition.
2
Zone Bypassed
This indicates that a system operator has manually isolated the
corresponding zone. Refer to Isolating Zones on page 15 for information
on how to manually isolate a zone(s) prior to arming the system.
3
Zone Trouble
This indicates that a zone was left unsealed after the end of exit time.
Table 10: Zone Status Display Descriptions
System Status
The system status information is divided up into 4 digits. The first digit of the system status
display indicates whether the system is armed or disarmed (8=Disarmed / 9 = Armed).
The second digit on the system status display indicates which codepad alarm was triggered
by the operator (0 = No Codepad Alarm / 1 = Codepad Panic or Duress Alarm / 2 = Codepad
Fire Alarm / 3 = Codepad Medical Alarm).
The third digit on the system status display indicates when the AC mains supply has failed (0
= AC Supply is normal / 1 = AC Supply has failed).
The fourth digit on the system status display indicates when a system fault has occurred at
the control panel (0 = System Normal – There is no faults / 1 = System Fault – There is a
fault registered by the control panel).
!"#$%&"'()* Operators Manual 29
Electronics Design and Manufacturing Pty Limited ISSUE160.DOC
Page view 28
1 ... 28 29 30 ... 44

Comments to this Manuals