Bosch Vision 300 Operating User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
18 en | Standard Controls Universal Camera Setup Software
F.01U.172.623 | 1.0 | 2011.10 User Manual Bosch Security Systems, Inc.
Other protocols use an add point method, where Start Recording and Stop Recording are
used in the same way, but instead of manual control in the middle, Add Tour Point is used to
insert a preset position with the options specified: Preset, Dwell and Speed.
4.8 Reset MIC
Accessed from File > Reset MIC, this sends out a command to reboot the software. This is not
a hardware reboot. The only way to reboot the hardware is to remove the power supply to the
MIC. The software reboot will take approximately 10 to 15 seconds, depending on the
software loaded.
4.9 Resetting Default Values After a Protocol Change
After any protocol change or a firmware (FW) upgrade, MIC cameras MUST be reset to their
default values. For Camset 4.0, follow these steps:
1. Open the Universal Camset software.
2. Set the appropriate values in the Cam-set Protocol, MIC Model, and IP Address fields (at
the bottom left of the main window).
3. Test for control. If control is not possible, repower the unit and check the camera
address on the Video Out or in the Boot Messages box. The address is sometimes
changed during the protocol changes. For example, when changing protocols from Pelco
to Bosch, the MIC address is changed to 54; the unit will not Pan left, and will only Tilt in
one direction.
4. Select Settings > General Control.
5. Click the Clear button under both Soft Stops and Non-Dwell Zone sections of the
window, and then click the Find End Stops button.
6. Select Settings > Default Loader.