Bosch DIP-7082-8HD Installation Guide Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
Finish configuration page
This page is used for providing a global default password for all devices that are not currently
protected by a password.
After clicking Save and activate the configuration is activated.
After successful activation the Activate Configuration page is displayed again. Now you can
store a backup of the configuration if desired: Click Save backup copy.
Notice!
We recommend saving the configuration after each change on an external storage media, for
example, USB drive. After recovering the system you can import this backup copy.
Using Bosch VMS Configuration Client
Assigning device IP addresses
If the IP addresses of devices that should be added do not fall within the same IP range as the
DIVAR IP, we recommend using the Bosch VMS Configuration Client.
To assign device IP addresses:
1. On the Bosch VMS default screen, double-click the Configuration Client icon
to
change device network settings. The application starts.
2. Enter the following, then click OK.
User name: admin
Password: no password required (if not set with the wizard)
Connection: 127.0.0.1
3. On the Hardware menu, click Initial Device Scan.
The application performs a network scan for all defaulted devices.
4. To assign all devices at once, click Select All, then right-click the selected devices, then
click SetIP Addresses. The Set IP Addresses dialog box is displayed.
4.5
4.5.1
28 en | System setup - first steps DIVAR IP 7000 2U
2014.01 | V3 | DOC Quick Installation Guide Bosch Sicherheitssysteme GmbH