Lift the appliance against the wall to engage in the top support
plate and lower onto the manifold assembly. Refer to Fig. 17.
Tighten the gas and water connections. Lower the facia and fit a
discharge pipe to the relief valve leading it away from any electric's.
The pipe must not be less than 15mm in diameter and must run
continuously downward outside the appliance. Refer to Fig 47.
If the optional internally fitted diverter valve is to be connected
then full instructions are sent with the valve. Refer to Fig. 20.
11.7 Air and Flue Duct Preparation
The method of installation of the flue system may be varied to
suit the actual site conditions. The instructions for connecting
and fixing the ducts must, however, be strictly followed.
Unpack the flue spigot, restrictor ring and clamping rings from the
Flue Spigot Kit in the boiler Installation Pack. Fit the spigot to the
boiler top panel with the four screws provided in the Flue Spigot Kit.
IMPOR
TANT Check the maximum flue length and if it is less than 1m
total overall length then fit the restrictor ring as shown in Fig. 21
.
24SBi - 75mm Horizontal flue up to 1m
- 75mm Vertical flue up to 1m
15SBi - 74mm Horizontal flue up to 1m
- 79mm Vertical flue up to 1m
The standard telescopic flue assembly is suitable for flues from
425mm up to 725mm measured from the centre-line of the
boiler flue outlet to the outer face of the wall. Refer to Fig.22.
14
Fig. 17 . Fixing the appliance to the wall mounting plate.
Appliance
Pre-plumbing
manifold
Keep
Appliance
Vertical
Step. 1
Rest the appliance on
the pre-plumbing
manifold and push
backwards engaging
the valves.
Check that all the
O-Rings are in place.
Step. 2
Secure the top with
M6 nuts and washers
(2).
Step.3
Secure the bottom
with the caps and
washers (3).
Fig.18. Appliance casing and control
equipment fixings.
Inner casing
cover
screws (4)
Side casing
fixing
screws (4)
Facia panel
fixing
screws (2)
Connections
cover fixing
screws (3)
24SBi
Fig.19. Flow manifold assembly
IMPORTANT
DO NOT REMOVE
THIS CLIP!
1. Flow manifold assembly
2. Connector
3. Clips (Removable)
4. Assembly mounting
plate
5. Filling Loop
6. Protection cap
3
5
1
4
6
2
Page view 13