Bosch ZSB 30-2 A Operations Instructions Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
Converting the appliance to different gas types | 51
6 720 644 143 (2010/09)
B Remove the gas throttle seat with a screw driver as
shown in Fig. 49.
Fig. 49
B Adjust the gas flow throttle to set the CO
2
or O
2
level
for maximum rated output according to the table.
Fig. 50
B Briefly press the central heating boost button .
The display shows the flow temperature in alternation
with = minimum rated heat output.
B Measure the CO
2
or O
2
level.
B Remove the sealed brass screw from gas valve
adjusting screw and set CO
2
or O
2
level for minimum
rated heat output.
Fig. 51
B Re-check settings at maximum and minimum rated
output and re-adjust if necessary.
B Repeatedly press the central heating boost button
until the light goes out.
The display will show the CH flow temperature again.
B Record the CO
2
or O
2
levels in the commissioning log.
B Remove flue gas probe from flue gas testing point and
refit sealing plug.
B Seal the gas valve and gas throttle.
max. rated heat
output
min. rated
heat output
Gas Type CO
2
O
2
CO
2
O
2
NG (23) 9.6 % 3,6 % 9.0 % 4,7 %
LPG (Propane) 10.8 % 4.6 % 10.2% 5.5 %
LPG (Butane) 12.2 % 2.8 % 11.5 % 3.8 %
Table 20
1 .
2 .
6 7 2 0 6 1 2 6 5 9 - 3 7 . 1 R
6 7 2 0 6 1 2 6 5 9 - 3 8 . 1 R
6 720 614 090-22.1O
1
2
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 79 80

Comments to this Manuals