MANAGED SWITCH SPECIFICATION GUIDE | STANDARDS COMPLIANCE – ENVIRONMENTAL – ELECTRICAL
7
CNGE8FX4TX4MS CNGE2FE8MSPOE CWFE8TX8MS CWGE2FE8MSPOE CWGE9MS
FCC Part 15 Class A, UL,
FCC, CE, IEC and NEMA
TS1/TS2
FC
C Part 15 Class A, UL,
FCC and CE
FCC Part 15 Class A, UL,
FCC and CE
FCC Part 15 Class A, UL,
FCC and CE
FCC Part 15 Class A, UL,
FCC and CE
• IEEE802.3
10Base-T Ethernet
• IEEE802.3u
100Base-TX /100Base-FX
• IEEE802.3z Gigabit fiber
• IEEE802.3ab 1000Base-T
• IEEE802.3x Flow Control
and Back Pressure
• IEEE802.3ad Port trunk
with LACP
• IEEE802.1d
Spanning Tree/
IEEE802.1w Rapid
Spanning Tree
• IEEE802.1p Class of
Service
• IEEE802.1q VLAN Tag
• IEEE802.1x User
Authentication (Radius)
• IEEE802.1ab LLDP
• IEEE802.3
10Base-T Ethernet
• IEEE802.3u 100Base-
TX/100Base-FX
• IEEE802.3z Gigabit fiber
• IEEE802.3ab 1000Base-T
• IEEE802.3x Flow Control
and Back Pressure
• IEEE802.3ad Port trunk
with LACP
• IEEE802.1d
Spanning Tree/
IEEE802.1w Rapid
Spanning Tree
• IEEE802.1p Class of
Service
• IEEE802.1q VLAN Tag
• IEEE802.1x User
Authentication (Radius)
• IEEE802.3af Power over
Ethernet
• IEEE802.1ab LLDP
• IEEE802.3
10Base-T Ethernet
• IEEE802.3u 100Base-
TX/100Base-FX
• IEEE802.3x Flow Control
and Back Pressure
• IEEE802.3ad Port trunk
with LACP
• IEEE802.1d Spanning
Tree
• IEEE802.1p Class of
Service
• IEEE802.1q VLAN Tag
• IEEE802.3
10Base-T Ethernet
• IEEE802.3u 100Base-
TX/100Base-FX
• IEEE802.3z Gigabit fiber
• IEEE802.3ab 1000Base-T
• IEEE802.3x Flow Control
and Back Pressure
• IEEE802.3ad Port trunk
with LACP
• IEEE802.1d Spanning
Tree/ IEEE802.1w Rapid
Spanning Tree
• IEEE802.1p Class of
Service
• IEEE802.1q VLAN Tag
• IEEE802.1x User
Authentication (Radius)
• IEEE802.3af Power over
Ethernet
• IEEE802.1ab LLDP
• IEEE802.3
10Base-T Ethernet
• IEEE802.3u 100Base-
TX/100Base-FX
• IEEE802.3z Gigabit fiber
• IEEE802.3ab 1000Base-T
• IEEE802.3x Flow Control
and Back Pressure
• IEEE802.3ad Port trunk
with LACP
• IEEE802.1d Spanning
Tree/ IEEE802.1w Rapid
Spanning Tree
• IEEE802.1p Class of
Service
• IEEE802.1q VLAN Tag
• IEEE802.1x User
Authentication (Radius)
• IEEE802.1ab LLDP
CNGE8FX4TX4MS CNGE2FE8MSPOE CWFE8TX8MS CWGE2FE8MSPOE CWGE9MS
-40ºC – +75ºC -40ºC – +75ºC 0ºC – +50ºC 0ºC – +50ºC 0ºC – +50ºC
-40ºC – +85ºC -40ºC – +85ºC -40ºC – +85ºC -40ºC – +85ºC -40ºC – +85ºC
CNGE8FX4TX4MS CNGE2FE8MSPOE CWFE8TX8MS CWGE2FE8MSPOE CWGE9MS
24VDC Plug in Power
Supply, 90-264VAC,
50/60Hz
(Included)
PS48VDC-5ADIN
Recommended
Power Supply
AC 100V~240V 50/60Hz
48VDC 81W Plug-in Power
Supply 90~264VAC
50/60 Hz (Included)
AC 100V~240V 50/60Hz
DC (12V~48V) DC (45V ~ 52V) NA NA NA