Bosch Appliances Security Camera LTC 9384 User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
LTC 9384 Series | Instruction Manual | Installation
EN
|
10
Bosch Security Systems | September 1, 2004
5.6.3 Power Connections
The LTC 9384 Series Housings (except the
nontransformer LTC 9384/20NT version) allow the
use of 24VAC cameras, regardless of the supply
voltage to the housing. This is achieved via
transformer in the housing. The transformer's primary
supply power varies, depending on the model of
housing, (see Section 5.1 Model Designation). In the
115 volt and 230 volt models, the transformer also
supplies 24VAC power to the integral window
heater/defogger.
1. Use the liquid-tight fitting on the left-hand side
of the housing to route the power wire into the
housing.
FIGURE 5 Power Connections
2. A screw/terminal lug is provided for securing a
safety ground. Attach the terminal lug to the
cradle using the M4 x 10 screw provided.
FIGURE 6 Securing the Ground Wire
3. Pull any excess wire out of the cradle assembly
and tighten the fitting to 8.5 N.m to 9.0 N.m
(75in. lb to 80in. lb). This torque rating is
approximately 1 to 11⁄2 turns past the point
where the fitting starts to grip the wire. Failure
to do so will allow water to enter and damage
all electronic parts. Use a tie wrap (included) to
provide strain relief on the power cord at the
exit point (inside the unit).
Securely tighten all fittings to ensure a liquid-
tight seal. Failure to do so could allow water to
enter the housing and damage the camera and
lens.
Select the appropriate wiring instructions from this
section, depending on which Housing is being used:
5.6.4 LTC 9384/60 Housings
The LTC 9384/60 Housings can easily be used with
either 115 volt or 24 volt cameras.
The internal transformer provides 24VAC for both the
heater/defogger and 24 volt camera power (see
FIGURE 5).
For 115 Volt Cameras:
1. Installing a 115 volt camera into the
LTC 9384/60 housing requires the camera's
line cord to be cut and connected with the
transformer primary leads and the power
supply line (see FIGURE 7).
2. The secondary flying leads (white/black striped)
will not be used in this application, and should
be taped to prevent shorting. See wiring
diagram FIGURE 7 for clarification and
FIGURE5 for power connection drawings.
FIGURE 7 LTC 9384/60 Transformer Wired for
115 Volt Camera
Liquid-tight Fitting
(Shown Underneath)
CCD Camera
WAGO Connectors
(After Connecting Wires,
Push Into Cavity)
Power Cable
Tie Wraps
Fuse Holder
Transformer
M4 Screw
Terminal Lug
Black
115 VAC
Input
White
Red
24 VAC
To Heater/Defogger
White/
Black
Striped
To Camera
To Camera
To Heater/Defogger
Red
No Connection
White/
Black
Striped
6
5
2
1
12
11
8
7
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16