PSI 6500.XXX W1
12-4
1070 080 059-101 (2001.04) GB
12.3 Technical data, PSI 6500.XXX W1
Type 3-phase MF inverter, module designed for
recessed mounting
Weld timer integrated
I/O interface Slot for parallel, serial or fieldbus interface
Quality module Slot prepared for retrofitting
Degree of protection IP 20; designed for modular enclosure or for
installation in switchgear cabinets with IP 54
Inverter ambient temperature max. 45° C; If thermal outputs exceed
50% of the rated ouput, a cabinet cooling
system starts running, which adjusts the
ambient temperature to 35° C.
Cooling water 10 l/min.; max. 30° C
Temperature monitoring integrated
Storage temperature -25° C to +70° C
Corrosion The ambient air must be free of acids, caus-
tic solutions, corrosive agents, salts and
metal vapors of any major concentration
Humidity Humidity class F as per DIN 40040;
20° C at 90% relative humidity;
40° C at 50% relative humidity (as per
VDE 0113); Moisture condensation on the
MF inverters must be prevented.
Air pressure Any within a range of up to 2000 m above
sea level
Line voltage connection
grounded TN or TT system
400 V -20% to 480 V +10%; 50/60 Hz
Nominal system current;
max. continuous thermal current
660 A, with cubicle cooling unit
Max. output current 2400 A
Max. secondary current; depending
on the transformer used
120 kA (PSG 3100)
Voltage supply;
Weld timer CPU;
I/O interface
24 V DC; min. 19 V DC up to max. 30 V DC
as per EN 61131-2, (external power sup-
ply), or, alternatively, power supply from the
weld current system (internal power supply)
Clock frequency 1 kHz
Overvoltage protection MOV; Metal Oxide Varistor
Electrical connection, mains supply
and transformer
with cable lugs;
M10 bolts for each connection
Wire range 2 to 4 cables, 120 mm
2
each
Basic switchgear cabinet loss 100 W
Max. ventilating and cooling loss dis-
sipated via external water-cooler
4400 W
Switchgear cabinet loss at max. power 850 W
Weight approx. 70 kg, mech. load may be distributed
Mounting position vertical or with its back on mounting plate